Literature DB >> 14636913

Usefulness of shear stress pattern in predicting neointima distribution in sirolimus-eluting stents in coronary arteries.

Frank J H Gijsen1, Remko M Oortman, Jolanda J Wentzel, Johan C H Schuurbiers, Kengo Tanabe, Muzaffer Degertekin, Jurgen M Ligthart, Attila Thury, Pim J de Feyter, Patrick W Serruys, Cornelis J Slager.   

Abstract

The true 3-dimensional neointimal thickness distribution in sirolimus-eluting stents was investigated in relation to the shear stress distribution, which was obtained from computational fluid dynamics calculations. Small pits were observed between the stent struts in all patients, and a significant inverse relation between neointimal thickness and shear stress was found, indicating that deeper pits were present in the outside curve of the stented segments.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14636913     DOI: 10.1016/j.amjcard.2003.08.017

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  15 in total

1.  Three-dimensional imaging for the guidance of coronary interventional procedures: impact on clinical decision making?

Authors:  Paul Schoenhagen
Journal:  Int J Cardiovasc Imaging       Date:  2004-12       Impact factor: 2.357

2.  Coronary dilatation 10 weeks after paclitaxel-eluting stent implantation. No role of shear stress in lumen enlargement?

Authors:  Michail I Papafaklis; Christos S Katsouras; Panagiotis E Theodorakis; Christos V Bourantas; Dimitrios I Fotiadis; Lampros K Michalis
Journal:  Heart Vessels       Date:  2007-07-20       Impact factor: 2.037

3.  Fusion of optical coherence tomographic and angiographic data for more accurate evaluation of the endothelial shear stress patterns and neointimal distribution after bioresorbable scaffold implantation: comparison with intravascular ultrasound-derived reconstructions.

Authors:  Christos V Bourantas; Michail I Papafaklis; Lampros Lakkas; Antonis Sakellarios; Yoshinobu Onuma; Yao-Jun Zhang; Takashi Muramatsu; Roberto Diletti; Paschalis Bizopoulos; Fanis Kalatzis; Katerina K Naka; Dimitrios I Fotiadis; Jin Wang; Hector M Garcia Garcia; Takeshi Kimura; Lampros K Michalis; Patrick W Serruys
Journal:  Int J Cardiovasc Imaging       Date:  2014-01-24       Impact factor: 2.357

4.  Impact of bifurcation dual stenting on endothelial shear stress.

Authors:  Henry Y Chen; Bon-Kwon Koo; Ghassan S Kassab
Journal:  J Appl Physiol (1985)       Date:  2015-07-16

5.  Superficial wall stress: the long awaited comprehensive biomechanical parameter to objectify and quantify our intuition.

Authors:  Juan Luis Gutiérrez-Chico
Journal:  Int J Cardiovasc Imaging       Date:  2018-06-06       Impact factor: 2.357

6.  Impact of stent implantation on endothelial shear stress.

Authors:  F Economou; S Katranas; G Giannoglou; K Gemitzis; I Styliadis; G Efthimiadis; H Karvounis; A Ziakas
Journal:  Herz       Date:  2016-10-12       Impact factor: 1.443

7.  Effects of local hemodynamics and plaque characteristics on neointimal response following bioresorbable scaffolds implantation in coronary bifurcations.

Authors:  Miao Chu; Juan Luis Gutiérrez-Chico; Yingguang Li; Emil N Holck; Su Zhang; Jiayue Huang; Zehang Li; Lianglong Chen; Evald H Christiansen; Jouke Dijkstra; Niels R Holm; Shengxian Tu
Journal:  Int J Cardiovasc Imaging       Date:  2019-10-30       Impact factor: 2.357

8.  Hemodynamic alternations following stent deployment and post-dilation in a heavily calcified coronary artery: In silico and ex-vivo approaches.

Authors:  Peshala T Gamage; Pengfei Dong; Juhwan Lee; Yazan Gharaibeh; Vladislav N Zimin; Luis A P Dallan; Hiram G Bezerra; David L Wilson; Linxia Gu
Journal:  Comput Biol Med       Date:  2021-10-21       Impact factor: 4.589

9.  Assessment of potential relationship between wall shear stress and arterial wall response after bare metal stent and sirolimus-eluting stent implantation in patients with diabetes mellitus.

Authors:  Nobuaki Suzuki; Hitesh Nanda; Dominick J Angiolillo; Hiran Bezerra; Manel Sabaté; Pilar Jiménez-Quevedo; Fernando Alfonso; Carlos Macaya; Theodore A Bass; Olusegun J Ilegbusi; Marco A Costa
Journal:  Int J Cardiovasc Imaging       Date:  2007-10-31       Impact factor: 2.357

10.  Tissue coverage of a hydrophilic polymer-coated zotarolimus-eluting stent vs. a fluoropolymer-coated everolimus-eluting stent at 13-month follow-up: an optical coherence tomography substudy from the RESOLUTE All Comers trial.

Authors:  Juan Luis Gutiérrez-Chico; Robert Jan van Geuns; Evelyn Regar; Willem J van der Giessen; Henning Kelbæk; Kari Saunamäki; Javier Escaned; Nieves Gonzalo; Carlo di Mario; Francesco Borgia; Eveline Nüesch; Héctor M García-García; Sigmund Silber; Stephan Windecker; Patrick W Serruys
Journal:  Eur Heart J       Date:  2011-06-09       Impact factor: 29.983

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.