G Sandqvist1, M Eklund. 1. Department of Rheumatology, Lund University Hospital, S-221 85 Lund, Sweden.
Abstract
OBJECTIVE: Hand Mobility in Scleroderma (HAMIS) is a new hand function test developed for adults who have systemic sclerosis. HAMIS consists of 9 items designed to measure all movements assessed in an ordinary range of motion (ROM)-measured hand test. The aim of this study was to examine the reliability of the test. METHODS: Two observers (one occupational therapist and one physiotherapist) performed the assessments independently of each other on 30 adult subjects. There were 25 women and 5 men in the sample (mean age 53 years, average time since diagnosis 4 years). Subjects were tested twice by each rather. RESULTS: Internal consistency ranged from 0.80 to 0.85 (Cronbach's alpha). Agreement between the two observers was good for all items (estimated kappa 0.52 to 1.00). The agreement between the observers' first and second assessments was moderate to very good for most items (estimated kappa 0.48 to 1.00), but not for the assessment of supination (estimated kappa 0.25 to 0.59). CONCLUSION: HAMIS is a reliable instrument for evaluation of hand function on scleroderma patients.
OBJECTIVE: Hand Mobility in Scleroderma (HAMIS) is a new hand function test developed for adults who have systemic sclerosis. HAMIS consists of 9 items designed to measure all movements assessed in an ordinary range of motion (ROM)-measured hand test. The aim of this study was to examine the reliability of the test. METHODS: Two observers (one occupational therapist and one physiotherapist) performed the assessments independently of each other on 30 adult subjects. There were 25 women and 5 men in the sample (mean age 53 years, average time since diagnosis 4 years). Subjects were tested twice by each rather. RESULTS: Internal consistency ranged from 0.80 to 0.85 (Cronbach's alpha). Agreement between the two observers was good for all items (estimated kappa 0.52 to 1.00). The agreement between the observers' first and second assessments was moderate to very good for most items (estimated kappa 0.48 to 1.00), but not for the assessment of supination (estimated kappa 0.25 to 0.59). CONCLUSION: HAMIS is a reliable instrument for evaluation of hand function on sclerodermapatients.
Authors: Kathryn S Torok; Nancy A Baker; Mary Lucas; Robyn T Domsic; Robert Boudreau; Thomas A Medsger Journal: Clin Exp Rheumatol Date: 2010-06-10 Impact factor: 4.473
Authors: Henrik Pettersson; Helene Alexanderson; Janet L Poole; Janos Varga; Malin Regardt; Anne-Marie Russell; Yasser Salam; Kelly Jensen; Jennifer Mansour; Tracy Frech; Carol Feghali-Bostwick; Cecília Varjú; Nancy Baldwin; Matty Heenan; Kim Fligelstone; Monica Holmner; Matthew R Lammi; Mary Beth Scholand; Lee Shapiro; Elizabeth R Volkmann; Lesley Ann Saketkoo Journal: Best Pract Res Clin Rheumatol Date: 2021-07-01 Impact factor: 4.991
Authors: Roger Hesselstrand; Johanna Carlestam; Marie Wildt; Gunnel Sandqvist; Kristofer Andréasson Journal: Arthritis Res Ther Date: 2015-11-19 Impact factor: 5.156