Literature DB >> 14633190

Effects of different propofol infusion rates on EEG activity and AEP responses in rats.

L M Antunes1, J V Roughan, P A Flecknell.   

Abstract

Parameters calculated from the auditory-evoked potential (AEP) recorded over the auditory cortex and from the electroencephalogram (EEG) recorded over the near vertex were compared in rats at three different infusion rates of propofol (62.5, 35 and 25 mg/kg/h). Depth of anaesthesia was assessed clinically using the strength of the pedal withdrawal reflex. Well-defined AEP responses were consistently obtained. As the propofol concentration was reduced, peak latencies decreased and peak to peak amplitudes increased. Amplitude and latency values were closely associated with the strength of the pedal withdrawal responses. Parameters calculated from the EEG showed no significant change as the propofol concentration was reduced. Periods of burst suppression became more frequent as the propofol infusion rate was increased. The study showed some of the difficulties that may be encountered when using EEG as a tool to assess depth of anaesthesia during propofol infusion. The AEP showed dose dependent changes in rats at different infusion rates of propofol. However, large variability between animals limits the use of this technique for monitoring depth of anaesthesia.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14633190     DOI: 10.1046/j.1365-2885.2003.00499.x

Source DB:  PubMed          Journal:  J Vet Pharmacol Ther        ISSN: 0140-7783            Impact factor:   1.786


  4 in total

1.  The effect of different anesthetics on neurovascular coupling.

Authors:  Maria Angela Franceschini; Harsha Radhakrishnan; Kiran Thakur; Weicheng Wu; Svetlana Ruvinskaya; Stefan Carp; David A Boas
Journal:  Neuroimage       Date:  2010-03-27       Impact factor: 6.556

2.  Increased electroencephalographic gamma activity reveals awakening from isoflurane anaesthesia in rats.

Authors:  J Kortelainen; X Jia; T Seppänen; N Thakor
Journal:  Br J Anaesth       Date:  2012-08-19       Impact factor: 9.166

3.  Connection changes in somatosensory cortex induced by different doses of propofol.

Authors:  Zhaoduan Li; Xingkui Liu; Yi Zhang; Jinshan Shi; Yu Zhang; Peng Xie; Tian Yu
Journal:  PLoS One       Date:  2014-02-07       Impact factor: 3.240

4.  Effect of transcutaneous acupoint electrical stimulation on propofol sedation: an electroencephalogram analysis of patients undergoing pituitary adenomas resection.

Authors:  Xing Liu; Jing Wang; Baoguo Wang; Ying Hua Wang; Qinglei Teng; Jiaqing Yan; Shuangyan Wang; You Wan
Journal:  BMC Complement Altern Med       Date:  2016-01-27       Impact factor: 3.659

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.