Literature DB >> 14632096

Comparison of two manual methods of nitrogen dioxide determination in ambient air.

S K Goyal1.   

Abstract

Sodium arsenite (modified Jacobs and Hochheiser method; hereafter referred as SA), the most widely used manual monitoring method for determination of nitrogen dioxide (NO2) in ambient air, particularly in developing countries has been evaluated and compared with US EPA recommended equivalent method of TGS-ANSA (hereafter referred as ANSA). NO2 concentrations generated from laboratory test atmosphere were analyzed by these two methods and were compared statistically. Laboratory evaluations showed that SA method has high sensitivity to different sampling conditions, which normally vary during actual field monitoring. Hence, correction factors for absorption efficiency were estimated for SA and ANSA methods. Absorption efficiency of NO2 in SA method was found to be much lower (64%) as against the reported value of 82% at the method recommended sampling conditions, whereas for ANSA method, it was found 1.0 as against the reported value of 0.93. After applying derived correction factors, both the methods produced almost similar concentration values of NO2.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14632096     DOI: 10.1023/a:1026179030146

Source DB:  PubMed          Journal:  Environ Monit Assess        ISSN: 0167-6369            Impact factor:   2.513


  4 in total

1.  A new method for measuring average 24-hour nitrogen dioxide concentrations in the atmosphere.

Authors:  D A Levaggi; W Siu; M Feldstein
Journal:  J Air Pollut Control Assoc       Date:  1973-01

2.  Field methods for the determination of nitrogen dioxide in air.

Authors:  A A Christie; R G Lidzey; D W Radford
Journal:  Analyst       Date:  1970-05       Impact factor: 4.616

3.  An efficient absorbing reagent for nitrogen dioxide.

Authors:  T Nash
Journal:  Atmos Environ       Date:  1970-11       Impact factor: 4.798

4.  Effect of sample flow rate and sampling duration on the absorption of NO2 in the sodium arsenite monitoring method.

Authors:  S K Goyal
Journal:  J Environ Monit       Date:  2002-08
  4 in total
  2 in total

1.  Effect of analytical techniques on measured ambient NO2 concentrations.

Authors:  S K Goyal; A G Gavane
Journal:  Environ Monit Assess       Date:  2005-06       Impact factor: 2.513

Review 2.  Passive dosimeters for nitrogen dioxide in personal/indoor air sampling: a review.

Authors:  Chang Ho Yu; Maria T Morandi; Clifford P Weisel
Journal:  J Expo Sci Environ Epidemiol       Date:  2008-04-30       Impact factor: 5.563

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.