The choice of stent-graft for endovascular repair of abdominal aortic aneurysm.

T A M Chuter1.   

Abstract

The aim of this study was to explain variations in the results of endovascular aneurysm repair as a consequences of device design. Low profile, trackable systems, such as Zenith and Excluder, rarely fail to traverse the iliac arteries, even in the presence of iliac tortuosity or stenosis. In most patients, optimal sizing is only possible with systems, such as Zenith, Talent, and Quantum lp, that have a wide range of diameters. Short, angulated necks call for a high degree of flexibility and secure, barb-enhanced proximal fixation, which are features of Excluder, Zenith and Ancure. The main risk factors for rupture are migration, type III endoleak, and aneurysm dilatation. Migration rates are high for devices, such as AneuRx, that have neither barbs nor suprarenal stents. Aneurysm shrinkage occurs at high rates with non-porous stent-grafts, such as Zenith, Talent, and Ancure, but at far lower rates with porous stent-grafts, such as Excluder and AneuRx. Type III endoleak, due to fabric failure or component separation, was a common failure mode for the Vanguard device, but is rare with newer devices. Suture breakage, barb separation and stent breakage occur frequently, yet clinical consequences, such as endoleak or rupture, are rare. Graft thrombosis is also unusual when the prostheses is fully-stented. In conclusion, modern devices are more versatile, more effective, and more durable than their first generation counterparts.

Entities:  

Mesh:

Year:  2003        PMID: 14627224

Source DB:  PubMed          Journal:  J Cardiovasc Surg (Torino)        ISSN: 0021-9509            Impact factor:   1.888


  3 in total

Review 1.  Analysis of prosthetic cardiac devices: a guide for the practising pathologist.

Authors:  J Butany; M J Collins
Journal:  J Clin Pathol       Date:  2005-02       Impact factor: 3.411

2.  Causes of late mortality after endovascular and open surgical repair of infrarenal abdominal aortic aneurysms.

Authors:  Philip P Goodney; Dale Tavris; F Lee Lucas; Thomas Gross; Elliott S Fisher; Samuel R G Finlayson
Journal:  J Vasc Surg       Date:  2010-04-10       Impact factor: 4.268

3.  An in Vitro Twist Fatigue Test of Fabric Stent-Grafts Supported by Z-Stents vs. Ringed Stents.

Authors:  Jing Lin; Robert Guidoin; Jia Du; Lu Wang; Graeham Douglas; Danjie Zhu; Mark Nutley; Lygia Perron; Ze Zhang; Yvan Douville
Journal:  Materials (Basel)       Date:  2016-02-16       Impact factor: 3.623

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.