Literature DB >> 14623785

A comparison of polyacrylamide gels and radiochromic film for source measurements in intravascular brachytherapy.

M N Amin1, M A Horsfield, D E Bonnett, M J Dunn, M Poulton, P F Harding.   

Abstract

For intravascular brachytherapy with catheter-based systems, AAPM Task Group 60 has recommended measurements that should be made to characterize the sources. Beta emitters, including (90)Sr/(90)Y are ideal for intravascular brachytherapy, but problems arise in measuring dose distributions in the high dose gradient region at short distances from the source. In this paper, measurements of radial and orthogonal dose distributions and dose profiles for a (90)Sr/(90)Y source train using polyacrylamide gel (PAG) dosimetry and a high-field 4.7 Tesla MRI scanner are presented and compared with measurements made with two types of radiochromic film, MD-55 and HD-810. For the PAG system, the dose distributions were determined with in-plane resolutions of 0.4 mm and 0.2 mm. The measurements of absorbed dose distributions both orthogonal and parallel to the source axis show good agreement between the PAG and radiochromic film. The absolute dose at a radial distance of 2 mm in the central 32 mm of a line parallel to the axis was measured. For the PAG the measured absorbed dose was 1.25% lower, for MD-55 4% higher and for the HD-810 1.6% higher when compared with the value given by the source calibration. These results confirm that both absorbed dose and dose distributions for high gradient vascular brachytherapy sources can be measured using PAG but the disadvantages of gel manufacture and the need for access to a high resolution scanner suggests that the use of radiochromic film is the method of choice.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14623785     DOI: 10.1259/bjr/25639755

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  3 in total

Review 1.  Polymer gel dosimetry.

Authors:  C Baldock; Y De Deene; S Doran; G Ibbott; A Jirasek; M Lepage; K B McAuley; M Oldham; L J Schreiner
Journal:  Phys Med Biol       Date:  2010-02-11       Impact factor: 3.609

Review 2.  Radiation Dosimetry by Use of Radiosensitive Hydrogels and Polymers: Mechanisms, State-of-the-Art and Perspective from 3D to 4D.

Authors:  Yves De Deene
Journal:  Gels       Date:  2022-09-19

3.  Verification and uniformity control of doses for Sr/Y intravascular brachytherapy sources using radiochromic film dosimetry.

Authors:  Bayram Demir; Asm Sabbir Ahmed; Erhan Babalik; Mustafa Demir; Tevfik Gürmen
Journal:  J Med Phys       Date:  2008-04
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.