Radiation doses to paediatric patients up to 5 years of age undergoing micturating cystourethrography examinations and its dependence on patient age: a Monte Carlo study.

M Fotakis1, E Molyvda Athanasopoulou, K Psarrakos, I Economou.   

Abstract

The effective dose received by children up to 5 years of age from micturating cystourethrography (MCU) examinations was estimated in this study. The MCU examination consisted of 5 radiological views, 2 anteroposterior (AP) and three oblique (OBL) views. Entrance surface doses (ESD) were measured with thermoluminescent dosimeters for 30 children. The average ESD values per view varied from 0.34 mGy up to 0.57 mGy. In order to calculate the organ and effective doses, Monte Carlo MCNP-4A radiation transport simulation code was used. It was applied to three mathematical phantoms representing newborn, 1 and 5 year old children and all the patients were classified in those three groups. The effective dose conversion factors (C(f)) were calculated as the ratio of effective dose over the entrance dose. The C(f) factors decrease as the children's age increases. Children simulated by a newborn mathematical phantom, had C(f) factors almost double those represented by a 1-year-old mathematical phantom. For children simulated by a 5 year old phantom, the C(f) factors for AP and OBL views were almost the same. This was true for both male and female patients. The mean effective dose per view for male and female patients was found to be E=0.16 mSv. The effective dose per examination for male patients was E=0.86+/-0.31 mSv and E=0.76+/-0.28 mSv for female patients.

Entities:  

Mesh:

Year:  2003        PMID: 14623783     DOI: 10.1259/bjr/31857098

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  4 in total

1.  Fluoroscopy-controlled voiding cystourethrography in infants and children: are the radiation risks trivial?

Authors:  Kostas Perisinakis; Maria Raissaki; John Damilakis; John Stratakis; John Neratzoulakis; Nicholas Gourtsoyiannis
Journal:  Eur Radiol       Date:  2005-12-03       Impact factor: 5.315

2.  Paediatric urological investigations--dose comparison between urology-related and CT irradiation.

Authors:  Mark Page; Cosmin Florescu; Lilian Johnstone; Daniel Habteslassie; Michael Ditchfield
Journal:  Pediatr Radiol       Date:  2013-02-05

3.  Ultra low-dose VCUG in children using a modern flat detectorunit.

Authors:  Sara Y S Linke; Ilias Tsiflikas; Klaus Herz; Phillipp Szavay; Sergios Gatidis; Jürgen F Schäfer
Journal:  Eur Radiol       Date:  2015-09-18       Impact factor: 5.315

4.  Effective dose estimation for pediatric voiding cystourethrography using an anthropomorphic phantom set and metal oxide semiconductor field-effect transistor (MOSFET) technology.

Authors:  Ryan Lee; Karen E Thomas; Bairbre L Connolly; Michelle Falkiner; Christopher L Gordon
Journal:  Pediatr Radiol       Date:  2009-02-25
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.