Literature DB >> 14623467

Electrochemiluminescent biosensors array for the concomitant detection of choline, glucose, glutamate, lactate, lysine and urate.

Christophe A Marquette1, Agnès Degiuli, Loïc J Blum.   

Abstract

A multifunctional bio-sensing chip was designed based on the electrochemiluminescent (ECL) detection of enzymatically produced hydrogen peroxide. Six different oxidases specific for choline, glucose, glutamate, lactate, lysine and urate were non-covalently immobilised on imidodiacetic acid chelating beads (glucose oxidase only) or on diethylaminoethyl (DEAE) anion exchanger beads, and spotted on the surface of a glassy carbon foil (25 mm(2) square), entrapped in PVA-SbQ photopolymer. The chip measurement was achieved by applying during 3 min a +850 mV potential between the glassy carbon electrode and a platinum pseudo-reference, while capturing a numeric image of the multifunctional bio-sensing chip with a CCD camera. The use of luminol supporting beads (DEAE-Sepharose) included in the sensing layer was shown to enable the achievement of spatially well defined signals, and to solve the hydrogen peroxide parasite signal which appeared between contiguous spots using luminol free in solution. The detection limits of the different biosensor were found to be 1 microM for glutamate, lysine and uric acid, 20 microM for glucose and 2 microM for choline and lactate. The detection ranges were 1-25 microM (uric acid), 1 microM-0.5 mM (glutamate and lysine), 20 microM-2 mM (glucose) and 2 microM-0.2 mM (choline and lactate). The ECL chip was used for the detection of glucose, lactate and uric acid in human serum matrix. Good correlations between measured and expected values were found without the need of internal calibration of the sample, demonstrating the potentiality of the ECL multifunctional bio-sensing chip.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14623467     DOI: 10.1016/s0956-5663(03)00225-2

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

1.  Simple Fabrication of Flexible Biosensor Arrays Using Direct Writing for Multianalyte Measurement from Human Astrocytes.

Authors:  James K Nolan; Tran N H Nguyen; Khanh Vy H Le; Luke E DeLong; Hyowon Lee
Journal:  SLAS Technol       Date:  2019-11-26       Impact factor: 3.047

Review 2.  Developments and Applications of Electrogenerated Chemiluminescence Sensors Based on Micro- and Nanomaterials.

Authors:  Sandra G Hazelton; Xingwang Zheng; Julia Xiaojun Zhao; David T Pierce
Journal:  Sensors (Basel)       Date:  2008-09-25       Impact factor: 3.576

3.  Stimuli-responsive polyguanidino-oxanorbornene membrane transporters as multicomponent sensors in complex matrices.

Authors:  Andreas Hennig; Gregory J Gabriel; Gregory N Tew; Stefan Matile
Journal:  J Am Chem Soc       Date:  2008-07-15       Impact factor: 15.419

Review 4.  Sensors for Fetal Hypoxia and Metabolic Acidosis: A Review.

Authors:  Gerard Cummins; Jessica Kremer; Anne Bernassau; Andrew Brown; Helen L Bridle; Holger Schulze; Till T Bachmann; Michael Crichton; Fiona C Denison; Marc P Y Desmulliez
Journal:  Sensors (Basel)       Date:  2018-08-13       Impact factor: 3.576

  4 in total