Literature DB >> 14623464

Detection of heavy metal ions using protein-functionalized microcantilever sensors.

Suman Cherian1, Rakesh K Gupta, Beth C Mullin, Thomas Thundat.   

Abstract

Microcantilevers functionalized with metal-binding protein, AgNt84-6, are demonstrated to be sensors for the detection of heavy metal ions like Hg(2+) and Zn(2+). AgNt84-6, a protein that has the ability to bind multiple atoms of Ni(2+), Zn(2+), Co(2+), Cu(2+), Cd(2+) and Hg(2+) was attached to the gold-coated side of silicon nitride cantilevers via linker groups. Upon exposure to 0.1 mM HgCl(2) and 0.1 mM ZnCl(2) solutions, the microcantilevers underwent bending corresponding to an expanding gold side. Exposure to a 0.1 mM solution of MnCl(2) solution did not result in a similar bending indicating a weak or no interaction of Mn(2+) ions with the AgNt84-6 protein. The microcantilever bending data were consistent with data from electrophoresis carried out on SDS-PAGE gels containing metal ions that showed protein interaction with Zn(2+) ions but not with Mn(2+) ions. Thus, we demonstrate that microcantilever bending can be used to discriminate between metal ions that bind and do not bind to AgNt84-6 protein in real time.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14623464     DOI: 10.1016/s0956-5663(03)00226-4

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

Review 1.  Approaches to increasing surface stress for improving signal-to-noise ratio of microcantilever sensors.

Authors:  Hai-Feng Ji; Benjamin D Armon
Journal:  Anal Chem       Date:  2010-03-01       Impact factor: 6.986

2.  Sensing surface PEGylation with microcantilevers.

Authors:  Natalija Backmann; Natascha Kappeler; Thomas Braun; François Huber; Hans-Peter Lang; Christoph Gerber; Roderick Y H Lim
Journal:  Beilstein J Nanotechnol       Date:  2010-11-22       Impact factor: 3.649

3.  Biosensing for the environment and defence: aqueous uranyl detection using bacterial surface layer proteins.

Authors:  David J R Conroy; Paul A Millner; Douglas I Stewart; Katrin Pollmann
Journal:  Sensors (Basel)       Date:  2010-05-10       Impact factor: 3.576

4.  Highly selective sensor for the detection of Hg2+ ions using homocysteine functionalised quartz crystal microbalance with cross-linked pyridinedicarboxylic acid.

Authors:  Dinesh Ramkrushna Rotake; Ajay Kumar; Anand D Darji; Jitendra Singh
Journal:  IET Nanobiotechnol       Date:  2020-09       Impact factor: 1.847

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.