Assessing the accuracy of routine photon correlation spectroscopy analysis of heterogeneous size distributions.

Christer B Frantzen1, Lars Ingebrigtsen, Merete Skar, Martin Brandl.   

Abstract

The aim of the current study was to investigate the ability of a fixed-angle routine photon correlation spectrometer (PCS) to resolve bimodal size distributions. The focus was on dispersions consisting of a majority of smaller and a minority of bigger particles. Monodisperse latex beads of sizes from 21 to 269 nm were measured first as single-size dispersions and then with various binary blends. For single-size dispersions, the mean diameters obtained were as indicated by the manufacturer, except for 21- and 34-nm particles, which were somewhat smaller. PCS analysis of blends of 21 + 102-nm and 34 + 102-nm particles resulted in bimodal distributions with particle diameters of the 2 peaks in the expected magnitude down to critical blending ratios of 0.002% and 0.08% of bigger particles, respectively. At these ratios, PCS results became inconsistent, and an increased number of monomodal results and/or high residuals were seen. For 21 + 102-nm blends, at even smaller ratios (0.001%), more consistent results were obtained again with predominantly monomodal distributions in the size range of the smaller particles (ie, the bigger particles were neglected). PCS analysis of blends of 21 + 269-nm particles yielded bimodal distributions with diameters within the expected magnitude as long as the content of bigger particles did not exceed 0.005%. Above this ratio, predominantly monomodal results with mean diameters in the magnitude of the bigger particles were obtained (ie, the smaller particles were neglected). In conclusion, a routine PCS instrument can resolve bimodal size distributions of colloidal dispersions only at certain ratios of the 2 subpopulations. Both low and high ratios lead to 1 of the 2 subpopulations being neglected.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14621968      PMCID: PMC2750629          DOI: 10.1208/pt040336

Source DB:  PubMed          Journal:  AAPS PharmSciTech        ISSN: 1530-9932            Impact factor:   3.246


  2 in total

1.  A comparison of LDL size determination using gradient gel electrophoresis and light-scattering methods.

Authors:  D O'Neal; P Harrip; G Dragicevic; D Rae; J D Best
Journal:  J Lipid Res       Date:  1998-10       Impact factor: 5.922

2.  Photon correlation spectroscopic study of the size distribution of phospholipid vesicles.

Authors:  J Goll; F D Carlson; Y Barenholz; B J Litman; T E Thompson
Journal:  Biophys J       Date:  1982-04       Impact factor: 4.033

  2 in total
  3 in total

1.  Characterization of a nanoparticulate drug delivery system using scanning ion occlusion sensing.

Authors:  Lin Yang; Murray F Broom; Ian G Tucker
Journal:  Pharm Res       Date:  2012-05-26       Impact factor: 4.200

2.  A method to determine the incorporation capacity of camptothecin in liposomes.

Authors:  Ann Mari Saetern; Gøril Eide Flaten; Martin Brandl
Journal:  AAPS PharmSciTech       Date:  2004-06-17       Impact factor: 3.246

3.  Effect of lyophilization and freeze-thawing on the stability of siRNA-liposome complexes.

Authors:  Preeti Yadava; Melissa Gibbs; Carlos Castro; Jeffrey A Hughes
Journal:  AAPS PharmSciTech       Date:  2007-12-29       Impact factor: 3.246

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.