Literature DB >> 14621145

Removal of indicator bacteria from municipal wastewater in an experimental two-stage vertical flow constructed wetland system.

C A Arias1, A Cabello, H Brix, N H Johansen.   

Abstract

The removal of sanitary indicator bacteria (total coliforms, faecal coliforms, and faecal streptococci) was studied in an experimental constructed wetland system consisting of (1) a 2-m3 three-chamber sedimentation tank, (2) a 5 m2 vertical flow constructed wetland, (3) a filter-unit with calcite aimed at removing phosphorus, and (4) a 10 m2 vertical flow constructed wetland. The indicator bacteria were enumerated before and after each unit of the wetland system during four monitoring episodes with different loading conditions. At a hydraulic loading rate of 520-1,370 mm/d, the first-stage vertical flow beds removed about 1.5 log-units of total coliforms, 1.7 log-units of faecal coliforms and 0.8 log-units of faecal streptococci. In the second stage bed receiving lower loadings both in term of concentration and quantity (260-690 mm/day), the eliminations were lower. It was not possible in the present study to identify any seasonal effects, but no measurements were done during summer. Recycling of treated effluent back to the sedimentation tank did not affect elimination. Area-based rate constants for the vertical flow wetland receiving effluent from the sedimentation tank averaged 3.2 m/d for total coliforms, 3.3 m/d for faecal coliforms and 2.1 m/d for faecal streptococci. The rate constants depended on loading rates. It is suggested that filtration is a major removal mechanism for bacterial indicator organisms in vertical flow constructed wetland systems.

Entities:  

Mesh:

Year:  2003        PMID: 14621145

Source DB:  PubMed          Journal:  Water Sci Technol        ISSN: 0273-1223            Impact factor:   1.915


  3 in total

1.  Quantification of diarrhea risk related to wastewater contact in Thailand.

Authors:  Aleix Ferrer; Hung Nguyen-Viet; Jakob Zinsstag
Journal:  Ecohealth       Date:  2012-02-07       Impact factor: 3.184

2.  Investigation of clay brick waste for the removal of copper, nickel and iron from aqueous solution: batch and fixed - bed column studies.

Authors:  Gobusaone Mokokwe; Moatlhodi Wise Letshwenyo
Journal:  Heliyon       Date:  2022-07-16

3.  Evaluation of Bed Depth Reduction, Media Change, and Partial Saturation as Combined Strategies to Modify in Vertical Treatment Wetlands.

Authors:  Ismael Vera-Puerto; Hugo Valdés; Christian Correa; Valeria Perez; Roberto Gomez; Erica Alarcon; Carlos Arias
Journal:  Int J Environ Res Public Health       Date:  2021-05-01       Impact factor: 3.390

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.