Literature DB >> 14620896

Usefulness of three-dimensional sonography in procedures of ablation for liver cancers: initial experience.

Hui-Xiong Xu1, Xiao-Yu Yin, Ming-De Lu, Xiao-Yan Xie, Zuo-Feng Xu, Guang-Jian Liu.   

Abstract

OBJECTIVE: To investigate the usefulness of three-dimensional sonography in procedures of ablation for liver cancers.
METHODS: Two- and three-dimensional sonography were used in guiding 18 chemical ablation procedures (7 with boiling carboplatin ablation and 11 with ethanol ablation) and 21 radio frequency ablation procedures for treatment of liver cancers. The applicator conspicuity depicted by the 2 imaging modalities, the confidence level of the operator in determining the position relationship between the applicator and the tumor using the 2 imaging modalities, and the alteration of ablation procedures were evaluated.
RESULTS: Three-dimensional sonography was better than two-dimensional sonography in delineation of multitined, expandable electrode tips in radio frequency ablation procedures, whereas the 2 modalities were equal in depicting percutaneous transhepatic cholangiography needle tips in chemical ablation procedures. Three-dimensional sonography significantly enhanced the confidence level in defining the spatial relationship between applicator and tumor in comparison with two-dimensional sonography (P < .01). Suboptimal applicator placement was detected in 6 (15%) of 39 ablation procedures on three-dimensional sonography: 3 chemical ablation procedures and 3 radio frequency ablation procedures. Applicator adjustment was required in 3 chemical ablation procedures. In 15 (38%) of 39 procedures, three-dimensional sonography allowed better visualization of the position relationship between the applicator and adjacent critical structures.
CONCLUSIONS: Three-dimensional sonography was useful in delineation of expandable radio frequency electrodes, improvement of operator confidence level, determination of applicator placement, and visualization of the position relationship between the applicator and adjacent critical structures during procedures of liver cancer ablation under image guidance.

Entities:  

Mesh:

Year:  2003        PMID: 14620896     DOI: 10.7863/jum.2003.22.11.1239

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  10 in total

Review 1.  Three dimensional ultrasound and prostate cancer.

Authors:  S S Mehta; A R Azzouzi; F C Hamdy
Journal:  World J Urol       Date:  2004-11-12       Impact factor: 4.226

2.  Liver ablation guidance with acoustic radiation force impulse imaging: challenges and opportunities.

Authors:  B J Fahey; S J Hsu; P D Wolf; R C Nelson; G E Trahey
Journal:  Phys Med Biol       Date:  2006-07-20       Impact factor: 3.609

3.  In vivo guidance and assessment of liver radio-frequency ablation with acoustic radiation force elastography.

Authors:  Brian J Fahey; Rendon C Nelson; Stephen J Hsu; David P Bradway; Douglas M Dumont; Gregg E Trahey
Journal:  Ultrasound Med Biol       Date:  2008-05-09       Impact factor: 2.998

4.  Era of diagnostic and interventional ultrasound.

Authors:  Hui-Xiong Xu
Journal:  World J Radiol       Date:  2011-05-28

5.  Laparoscopic microwave ablation of human liver tumours using a novel three-dimensional magnetic guidance system.

Authors:  David Sindram; Kerri A Simo; Ryan Z Swan; Sharif Razzaque; David J Niemeyer; Ramanathan M Seshadri; Erin Hanna; Iain H McKillop; David A Iannitti; John B Martinie
Journal:  HPB (Oxford)       Date:  2014-09-17       Impact factor: 3.647

6.  Real-time three-dimensional guided ultrasound targeting system for microwave ablation of liver tumours: a human pilot study.

Authors:  David Sindram; Ryan Z Swan; Kwan N Lau; Iain H McKillop; David A Iannitti; John B Martinie
Journal:  HPB (Oxford)       Date:  2011-01-27       Impact factor: 3.647

7.  Contrast-enhanced 3D ultrasound in the radiofrequency ablation of liver tumors.

Authors:  Edward Leen; Senthil Kumar; Shahid A Khan; Gavin Low; Keh Oon Ong; Paul Tait; Mike Averkiou
Journal:  World J Gastroenterol       Date:  2009-01-21       Impact factor: 5.742

8.  Imaging detection of new HCCs in cirrhotic patients treated with different techniques: Comparison of conventional US, spiral CT, and 3-dimensional contrast-enhanced US with the Navigator technique (Nav 3D CEUS)().

Authors:  F Giangregorio; G Comparato; M G Marinone; M Di Stasi; G Sbolli; G Aragona; P Tansini; F Fornari
Journal:  J Ultrasound       Date:  2009-02-26

9.  Analysis of refractive artifacts by reconstructed three-dimensional ultrasound imaging.

Authors:  Michiko Sato; Hideaki Ishida; Kei Konno; Tomoya Komatsuda; Kayoko Furukawa; Mamiko Yamada; Hitoshi Yagisawa; Yasuo Yoshida; Sumio Watanabe
Journal:  J Med Ultrason (2001)       Date:  2006-03       Impact factor: 1.878

10.  Contrast-Enhanced Ultrasound (CEUS) for Echographic Detection of Hepato Cellular Carcinoma in Cirrhotic Patients Previously Treated with Multiple Techniques: Comparison of Conventional US, Spiral CT and 3-Dimensional CEUS with Navigator Technique (3DNav CEUS).

Authors:  Francesco Giangregorio
Journal:  Cancers (Basel)       Date:  2011-03-30       Impact factor: 6.639

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.