Literature DB >> 14620895

Treated needles: do they facilitate sonographically guided biopsies?

Dana I Jandzinski1, Nancy Carson, Delphine Davis, Deborah J Rubens, Susan L Voci, Ronald H Gottlieb.   

Abstract

OBJECTIVE: We sought to compare needle visualization and diagnostic yield rates resulting from the use of several commercially available treated needles in sonographically guided biopsies.
METHODS: We conducted a randomized prospective study in which 61 patients (42 women and 19 men; mean age, 57 years; range, 19-84 years) were assigned to undergo biopsies (37 thyroid and 24 liver, 2 passes per patient) with 1 of 4 different 22-gauge needles: Teflon coated, etched tip, echogenic polymer coated, and untreated. Two blinded radiologists independently scored needle shaft and tip visualization from 0 (no visualization) to 4 (excellent visualization). After blinded cytologic evaluation, the individual passes were rated as adequate or inadequate for establishing a tissue diagnosis.
RESULTS: The echogenic polymer-coated needle had the highest mean score +/- SD for visualization of both the shaft (3.4 +/- 0.90) and tip (3.5 +/- 0.87) compared with the untreated (shaft, 2.2 +/- 0.77; P = 0.003; tip, 2.8 +/- 0.92; P = 0.01), Teflon-coated (shaft, 2.7 +/- 0.94; tip, 3.1 +/- 0.75), and etched tip (shaft, 3.0 +/- 0.82; tip, 3.0 +/- 0.56) needles. Diagnostic yield rates for the 4 different needle types were 75.0% for the echogenic polymer-coated, 64.7% for the Teflon-coated, 56.3% for the etched tip, and 75.0% for the untreated needles (no significant difference).
CONCLUSIONS: The echogenic polymer-coated needle was the best visualized of all needles evaluated, both treated and untreated. No significant difference was found in diagnostic yield rates, but that may be reflective of the relatively small sample size.

Entities:  

Mesh:

Year:  2003        PMID: 14620895     DOI: 10.7863/jum.2003.22.11.1233

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  7 in total

1.  Ultrasound-assisted musculoskeletal procedures: A practical overview of current literature.

Authors:  Nelson A Royall; Emily Farrin; David P Bahner; Stanislaw Pa Stawicki
Journal:  World J Orthop       Date:  2011-07-18

2.  Vibrating interventional device detection using real-time 3-D color Doppler.

Authors:  Matthew P Fronheiser; Salim F Idriss; Patrick D Wolf; Stephen W Smith
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008       Impact factor: 2.725

3.  Comparison of the coracoid and retroclavicular approaches for ultrasound-guided infraclavicular brachial plexus block.

Authors:  Nilgun Kavrut Ozturk; Ali Sait Kavakli
Journal:  J Anesth       Date:  2017-04-18       Impact factor: 2.078

4.  Optimal surface property for three-dimensional echo visualization.

Authors:  Shunsuke Asakura; Saki Nishikawa; Kazumasa Orihashi; Yoshio Inoue
Journal:  J Med Ultrason (2001)       Date:  2017-10-12       Impact factor: 1.314

5.  Do echo-enhanced needles improve time to cannulate in a model of short-axis ultrasound-guided vascular access for a group of mostly inexperienced ultrasound users?

Authors:  Michael P Phelan; Chuck Emerman; William F Peacock; Mathew Karafa; Nora Colburn; Kelly Buchanan
Journal:  Int J Emerg Med       Date:  2009-08-21

6.  Optimization of Cannula Visibility during Ultrasound-Guided Subclavian Vein Catheterization, via a Longitudinal Approach, by Implementing Echogenic Technology.

Authors:  Konstantinos Stefanidis; Mariantina Fragou; Nicos Pentilas; Gregorios Kouraklis; Serafim Nanas; Richard H Savel; Ariel L Shiloh; Michel Slama; Dimitrios Karakitsos
Journal:  Crit Care Res Pract       Date:  2012-04-23

7.  Comparative evaluation of two approaches of infraclavicular brachial plexus block for upper-limb surgeries.

Authors:  Chandni Sinha; Neeraj Kumar; Amarjeet Kumar; Ajeet Kumar; Anup Kumar
Journal:  Saudi J Anaesth       Date:  2019 Jan-Mar
  7 in total