| Literature DB >> 14617341 |
H S P Garritsen1, T Brune, F Louwen, J Wüllenweber, C Ahlke, U Cassens, R Witteler, W Sibrowski.
Abstract
To investigate whether packed red cells (PRCs) prepared from autologous cord blood-packed red cells (AC-PRCs) could be used as an alternative for homologous-packed red cells (H-PRCs), we developed a system to collect and prepare AC-PRCs and determined standard storage parameters during 35 days of storage in extended storage medium (Sag-mannitol). We collected and fractionated cord blood from 390 newborns. The amount and quality of the AC-PRCs were analysed. The bacterial contamination rate was 1.84%. Twelve AC-PRCs were stored for 35 days, and standard laboratory parameters were measured at day 1 and day 35. The initial laboratory parameters of the AC-PRCs were similar to the parameters of the H-PRCs. After 35 days, the AC-PRCs displayed an increased haemolysis rate compared to H-PRCs (1.1 versus 0.2%) and also a significant decreased adenosine triphosphate value (1.2 versus 2.3 micromol L(-1)). Haemoglobin, haematocrit and pH were comparable in both groups. AC-PRCs meet the quality criteria for H-PRCs after 35 days. Utilizing a closed collection system for cord blood and an extended storage medium will increase safety and quality and facilitate the routine transfusion of autologous red cells derived from cord blood.Entities:
Mesh:
Substances:
Year: 2003 PMID: 14617341 DOI: 10.1046/j.1365-3148.2003.00457.x
Source DB: PubMed Journal: Transfus Med ISSN: 0958-7578 Impact factor: 2.019