Literature DB >> 14616014

Combination of chiral capillary electrochromatography with electrospray ionization mass spectrometry: method development and assay of warfarin enantiomers in human plasma.

Jack Zheng1, Shahab A Shamsi.   

Abstract

The hyphenation of chiral capillary electrochromatography (CEC) with electrospray ionization mass spectrometry (ESI-MS) is very challenging but promising due to the fact that it combines sensitivity with high specificity and selectivity. In this work, CEC capillaries packed with (3R,4S)-Whelk-O1 chiral stationary phase were used for simultaneous enantioseparation of (+/-)-warfarin and its internal standard, (+/-)-coumachlor. Furthermore, both the chiral CEC separation and MS detection parameters were examined in detail. First, the influence of different column fabrication was investigated. Second, enantioseparation was optimized by varying CEC parameters, including acetonitrile concentration, buffer pH, and ionic strength. Under the optimum chiral CEC conditions, ESI-MS parameters such as sheath liquid pH and composition, sheath liquid flow rate, drying gas flow rate, drying gas temperature, nebulizer pressure, and fragmentor voltage were investigated to achieve maximum MS signals of the separated enantiomers. Finally, using solid-phase extraction as sample preparation method, (+/-)-warfarin spiked in 100-microL human plasma samples were analyzed. The calibration curves showed good linearity for both (R)-warfarin (R = 0.9979) and (S)-warfarin (R = 0.9978) enantiomers. The experimental limit of detection was approximately 25 ng/mL for both enantiomers. Even though the data are still preliminary, we can state with confidence that chiral CEC-ESI-MS has the potential to establish itself as a very powerful technique for the determination of enantiomeric ratios in human body fluid.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14616014     DOI: 10.1021/ac030193j

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  7 in total

Review 1.  Capillary Electrophoresis Mass Spectrometry: Developments and Applications for Enantioselective Analysis from 2011-2020.

Authors:  Shahab A Shamsi; Ferdoushi Akter
Journal:  Molecules       Date:  2022-06-27       Impact factor: 4.927

Review 2.  CEC: selected developments that caught my eye since the year 2000.

Authors:  Frantisek Svec
Journal:  Electrophoresis       Date:  2009-06       Impact factor: 3.535

3.  Development of a chiral micellar electrokinetic chromatography-tandem mass spectrometry assay for simultaneous analysis of warfarin and hydroxywarfarin metabolites: application to the analysis of patients serum samples.

Authors:  Xiaochun Wang; Jingguo Hou; Michael Jann; Yuen Yi Hon; Shahab A Shamsi
Journal:  J Chromatogr A       Date:  2012-11-26       Impact factor: 4.759

4.  Validation and Application of a Simple UHPLC-MS-MS Method for the Enantiospecific Determination of Warfarin in Human Urine.

Authors:  Osama Y Alshogran; Andrew J Ocque; François A Leblond; Vincent Pichette; Thomas D Nolin
Journal:  J Chromatogr Sci       Date:  2015-12-11       Impact factor: 1.618

5.  Optimized separation of beta-blockers with multiple chiral centers using capillary electrochromatography-mass spectrometry.

Authors:  William Bragg; Dean Norton; Shahab A Shamsi
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2008-11-01       Impact factor: 3.205

Review 6.  Two decades of studying non-covalent biomolecular assemblies by means of electrospray ionization mass spectrometry.

Authors:  Gillian R Hilton; Justin L P Benesch
Journal:  J R Soc Interface       Date:  2012-02-07       Impact factor: 4.118

Review 7.  Past, present, and future developments in enantioselective analysis using capillary electromigration techniques.

Authors:  Nicky de Koster; Charles P Clark; Isabelle Kohler
Journal:  Electrophoresis       Date:  2020-09-28       Impact factor: 3.535

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.