Literature DB >> 14615999

Comparison of ultraviolet femtosecond and nanosecond laser ablation inductively coupled plasma mass spectrometry analysis in glass, monazite, and zircon.

Franck Poitrasson1, Xianglei Mao, Samuel S Mao, Rémi Freydier, Richard E Russo.   

Abstract

We compared the analytical performance of ultraviolet femtosecond and nanosecond laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS). The benefit of ultrafast lasers was evaluated regarding thermal-induced chemical fractionation, that is otherwise well known to limit LA-ICPMS. Both lasers had a Gaussian beam energy profile and were tested using the same ablation system and ICPMS analyzer. Resulting crater morphologies and analytical signals showed more straightforward femtosecond laser ablation processes, with minimal thermal effects. Despite a less stable energy output, the ultrafast laser yielded elemental (Pb/U, Pb/Th) and Pb isotopic ratios that were more precise, repeatable, and accurate, even when compared to the best analytical conditions for the nanosecond laser. Measurements on NIST glasses, monazites, and zircon also showed that femtosecond LA-ICPMS calibration was less matrix-matched dependent and therefore more versatile.

Entities:  

Year:  2003        PMID: 14615999     DOI: 10.1021/ac034680a

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

1.  Analyte response in laser ablation inductively coupled plasma mass spectrometry.

Authors:  Zhongke Wang; Bodo Hattendorf; Detlef Günther
Journal:  J Am Soc Mass Spectrom       Date:  2006-03-06       Impact factor: 3.109

2.  Determination of seventeen major and trace elements in new float glass standards for use in forensic comparisons using laser ablation inductively coupled plasma mass spectrometry.

Authors:  José Almirall; Anuradha Akmeemana; Katelyn Lambert; Ping Jiang; Ela Bakowska; Ruthmara Corzo; Claudia Martinez Lopez; Edward Chip Pollock; Katrin Prasch; Tatiana Trejos; Peter Weis; Wim Wiarda; Huifang Xie; Peter Zoon
Journal:  Spectrochim Acta Part B At Spectrosc       Date:  2021-05       Impact factor: 3.752

3.  Dating the Martian meteorite Zagami by the ⁸⁷Rb-⁸⁷Sr isochron method with a prototype in situ resonance ionization mass spectrometer.

Authors:  F Scott Anderson; Jonathan Levine; Tom J Whitaker
Journal:  Rapid Commun Mass Spectrom       Date:  2015-01-30       Impact factor: 2.419

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.