Literature DB >> 14614945

Noninvasive muscle tension measurement using the novel technique of magnetic resonance elastography (MRE).

Thomas R Jenkyn1, Richard L Ehman, Kai-Nan An.   

Abstract

A novel method for direct measurement of the state of skeletal muscle contraction is introduced called magnetic resonance elastography (MRE). Such a technique is useful for avoiding the indeterminancy inherent in most inverse dynamic models of the musculoskeletal system. Within a standard MRI scanner, mechanical vibration is applied to muscle via the skin, creating shear waves that penetrate the tissue and propagate along muscle fibers. A gradient echo sequence is used with cyclic motion-encoding to image the propagating shear waves using phase contrast. Individual muscles of interest are identified and the shear wavelength in each is measured. Shear wavelength increases with increasing tissue stiffness and increasing tissue tension. Several ankle muscles were tested simultaneously in normal subjects. Applied ankle moment was isometrically resisted at several different foot positions. Shear wavelengths in relaxed muscle in neutral foot position was 2.34 +/- 0.47 cm for tibialis anterior (TA) and 3.13 +/- 0.24 cm for lateral gastrocnemius (LG). Wavelength increased in relaxed muscle when stretched (to 3.80 +/- 0.28 cm for TA in 45 degrees plantar-flexion and to 3.95 +/- 0.43 cm for LG in 20 degrees dorsi-flexion). Wavelength increased more significantly with contraction (to 7.71 +/- 0.97 cm in TA for 16 N m dorsi-flexion effort and to 7.90 +/- 0.34 cm in LG for 48 N m plantar-flexion effort). MRE has been shown to be sensitive to both passive and active tension within skeletal muscle making it a promising, noninvasive tool for biomechanical analysis. Since it is based on MRI technology, any muscle, however deep, can be interrogated using equipment commonly available in most health care facilities.

Entities:  

Mesh:

Year:  2003        PMID: 14614945     DOI: 10.1016/s0021-9290(03)00005-8

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  20 in total

1.  AN OVERVIEW OF ELASTOGRAPHY - AN EMERGING BRANCH OF MEDICAL IMAGING.

Authors:  Armen Sarvazyan; Timothy J Hall; Matthew W Urban; Mostafa Fatemi; Salavat R Aglyamov; Brian S Garra
Journal:  Curr Med Imaging Rev       Date:  2011-11

Review 2.  General review of magnetic resonance elastography.

Authors:  Gavin Low; Scott A Kruse; David J Lomas
Journal:  World J Radiol       Date:  2016-01-28

3.  Contemporary image-based methods for measuring passive mechanical properties of skeletal muscles in vivo.

Authors:  Lynne E Bilston; Bart Bolsterlee; Antoine Nordez; Shantanu Sinha
Journal:  J Appl Physiol (1985)       Date:  2018-09-20

4.  A comprehensive computational model of sound transmission through the porcine lung.

Authors:  Zoujun Dai; Ying Peng; Brian M Henry; Hansen A Mansy; Richard H Sandler; Thomas J Royston
Journal:  J Acoust Soc Am       Date:  2014-09       Impact factor: 1.840

5.  Comparison of Poroviscoelastic Models for Sound and Vibration in the Lungs.

Authors:  Zoujun Dai; Ying Peng; Hansen A Mansy; Richard H Sandler; Thomas J Royston
Journal:  J Vib Acoust       Date:  2014-07-25       Impact factor: 1.583

6.  Validation of shear wave elastography in skeletal muscle.

Authors:  Sarah F Eby; Pengfei Song; Shigao Chen; Qingshan Chen; James F Greenleaf; Kai-Nan An
Journal:  J Biomech       Date:  2013-07-30       Impact factor: 2.712

7.  Shear wave elastography characteristics of upper limb muscle in rigidity-dominant Parkinson's disease.

Authors:  Chang Wei Ding; Xin Song; Xin Yu Fu; Ying Chun Zhang; Pan Mao; Yu Jing Sheng; Min Yang; Cai Shan Wang; Ying Zhang; Xiao Fang Chen; Cheng Jie Mao; Wei Feng Luo; Chun Feng Liu
Journal:  Neurol Sci       Date:  2021-02-04       Impact factor: 3.307

Review 8.  Review of MR elastography applications and recent developments.

Authors:  Kevin J Glaser; Armando Manduca; Richard L Ehman
Journal:  J Magn Reson Imaging       Date:  2012-10       Impact factor: 4.813

9.  Quantitative sonoelastography for the in vivo assessment of skeletal muscle viscoelasticity.

Authors:  Kenneth Hoyt; Timothy Kneezel; Benjamin Castaneda; Kevin J Parker
Journal:  Phys Med Biol       Date:  2008-07-08       Impact factor: 3.609

10.  Anisotropic composite material phantom to improve skeletal muscle characterization using magnetic resonance elastography.

Authors:  Martina Guidetti; Gloria Lorgna; Margaret Hammersly; Phillip Lewis; Dieter Klatt; Pasquale Vena; Ramille Shah; Thomas J Royston
Journal:  J Mech Behav Biomed Mater       Date:  2018-09-25
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.