Literature DB >> 14613197

Improved solid-phase microextraction device for use in on-line immunoaffinity capillary electrophoresis.

Norberto A Guzman1.   

Abstract

A simple solid-phase microextraction device was fabricated for use in on-line immunoaffinity capillary electrophoresis (CE). The device, designed in the form of a four-part cross-shaped or cruciform configuration, includes a large-bore tube to transport samples and washing buffers and a small-bore fused-silica capillary for separation of analytes. At the intersection of the transport and separation tubes, a small cavity was fabricated, termed the analyte concentrator-microreactor, which contains four porous walls or semipermeable membranes (one for each inlet and outlet of the tubes) permitting the confinement of beads or suitable microstructures. The surface of the beads in the analyte concentrator carried a molecular recognition adsorbing chemical or affinity ligand material. The improved cruciform configuration of the analyte concentrator-microreactor device, designed for use in on-line immunoaffinity CE, enables it to specifically trap, enrich, and elute an analyte from any biological fluid or tissue sample extract without any sample pretreatment except filtration, centrifugation, and/or dilution allowing the separation and characterization of target analyte(s) with improved speed, sensitivity, and lower cost than existing techniques. As a model system, Fab' fragments derived from a purified immunoglobulin G (IgG) antibody were covalently bound to controlled-porosity glass and used as constituents of the analyte-microreactor device. The high-specificity polyclonal antibodies employed in these experiments were individually raised against the acidic nonsteroidal anti-inflammatory drugs ibuprofen and naproxen, and the neuropeptides angiotensin II, and neurotensin. These compounds, which were present in simple and complex matrices were captured by and eluted from the analyte concentrator-microreactor using a 50 mM sodium tetraborate buffer solution, pH 9.0, followed by a 100 nL plug of 300 mM glycine buffer, pH 3.4. Two analyte concentrators were tested independently: one containing Fab' fragments derived from antibodies raised against ibuprofen and naproxen; the other containing Fab' fragments derived from antibodies raised against angiotensin II and neurotensin. Each resulting electropherogram demonstrated the presence of two eluted materials in less than 20 min. Immunoaffinity CE performed in a cruciform structure was simpler and faster than previously reported in the literature using on-line microextraction devices designed in a linear format. The new concentration-separation system operated consistently for many runs, maintaining reproducible migration times and peak areas for every analyte studied.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14613197     DOI: 10.1002/elps.200305647

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  5 in total

1.  Chip-based immunoaffinity CE: application to the measurement of brain-derived neurotrophic factor in skin biopsies.

Authors:  Terry M Phillips; Edward F Wellner
Journal:  Electrophoresis       Date:  2009-07       Impact factor: 3.535

2.  Assessment of chemokine profiles in human skin biopsies by an immunoaffinity capillary electrophoresis chip.

Authors:  Heather Kalish; Terry M Phillips
Journal:  Methods       Date:  2011-12-17       Impact factor: 3.608

Review 3.  Immunoaffinity capillary electrophoresis as a powerful strategy for the quantification of low-abundance biomarkers, drugs, and metabolites in biological matrices.

Authors:  Norberto A Guzman; Timothy Blanc; Terry M Phillips
Journal:  Electrophoresis       Date:  2008-08       Impact factor: 3.535

4.  High efficiency reduction capability for the formation of Fab׳ antibody fragments from F(ab)2 units.

Authors:  Victor Crivianu-Gaita; Alexander Romaschin; Michael Thompson
Journal:  Biochem Biophys Rep       Date:  2015-04-25

5.  Extraction of Pregabalin in Urine Samples Using a Sulfonated Poly(ether ether ketone) Membrane.

Authors:  Chanbasha Basheer
Journal:  Int J Anal Chem       Date:  2021-05-31       Impact factor: 1.885

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.