Literature DB >> 1461204

Simple calculation of the electron-backscatter factor.

T Tabata1, R Ito.   

Abstract

The authors have studied the dependence of the electron-backscatter factor (EBF) on mean electron energy and on backscatterer atomic number by using the semiempirical depth-dose code EDMULT. A plane-parallel electron beam is assumed to be normally incident on a polystyrene slab, which is backed with a layer (backscatterer) of different materials of effectively semi-infinite thickness. A small air cavity to measure ionization is embedded in the polystyrene slab at the boundary facing the backscatterer. The EBF is defined as the ratio of the ionization with the backscatterer to the ionization with a full polystyrene medium, and is approximated by the ratio of the doses computed at the depth of the cavity. Values of EBF obtained show trends similar to the experimental data of Klevenhagen et al. [Phys. Med. Biol. 27, 263-373 (1982)], although the former are generally lower than the latter. When the typical energy spread of clinical electron beams is taken into account, the difference between the experimental and the calculated values is reduced. The present results also show the same trend of increase of the backscatter factor with increasing energy as observed by Klevenhagen et al. in some series of measurements for the lead backscatterer at the lowest energies. This is explained by the rapid buildup of the dose with depth for electrons of low initial energies incident on the full polystyrene medium.

Entities:  

Mesh:

Year:  1992        PMID: 1461204     DOI: 10.1118/1.596796

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  Evaluation of backscatter dose from internal lead shielding in clinical electron beams using EGSnrc Monte Carlo simulations.

Authors:  Rowen J De Vries; Steven Marsh
Journal:  J Appl Clin Med Phys       Date:  2015-11-08       Impact factor: 2.102

2.  Glamour, expression, and consequences of tattoos in radiation treatment.

Authors:  Paulina E Galavis; Nicholas J Sanfilippo; Indra J Das
Journal:  PLoS One       Date:  2019-08-07       Impact factor: 3.240

3.  Estimation of Backscatter from Internal Shielding in Electron Beam Radiotherapy Using Monte Carlo Simulations (EGSnrc) and Gafchromic Film Measurements.

Authors:  Sukhvir Singh; Manoj Kumar Semwal; C P Bhatt
Journal:  J Med Phys       Date:  2019-12-11
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.