Literature DB >> 14609694

Lateral mass screw-rod fixation of the cervical spine: a prospective clinical series with 1-year follow-up.

H Gordon Deen1, Barry D Birch, Robert E Wharen, Ronald Reimer.   

Abstract

BACKGROUND CONTEXT: Lateral mass plating has become the technique of choice for posterior cervical fixation. Although these systems are safe and reliable, they can be difficult to use in patients with abnormal cervical anatomy; screw placement can be compromised by the fixed hole spacing of the plate; screw back-out and other forms of implant failure can occur; and extension across the cervicothoracic junction can be problematic.
PURPOSE: To report a series of patients undergoing posterior cervical stabilization with a polyaxial screw-rod construct and to investigate whether this new system offers any advantages over existing methods of fixation. STUDY
DESIGN: A prospective study evaluating clinical and radiographic parameters in a consecutive series of patients treated with this technique. PATIENT SAMPLE: There were 21 patients in the study group. The surgical indication was cervical spondylosis in 14, trauma in 2, postsurgical kyphosis in 2 and 1 case each of congenital cervicothoracic stenosis, C7-T1 pseudarthrosis and basilar invagination with brainstem compression. OUTCOME MEASURES: Clinical indicators included age, gender, neurologic status, surgical indication and number of levels stabilized. Note was made of whether laminectomy and concomitant anterior reconstructive surgery were performed. Radiographic indicators included early postoperative computed tomography (CT) scan to check for screw placement and plain radiographs at subsequent visits.
METHODS: The participants in this study underwent posterior cervical stabilization using lateral mass screw-rod fixation. Clinical and radiographic assessment was carried out immediately after surgery, and 3, 6 and 12 months after surgery. One-year follow-up was obtained in all cases.
RESULTS: A total of 212 screws were implanted in 21 patients. Fixation was carried out over an average of 5.5 spinal segments (range, 2 to 11). The system was successfully implanted in all patients despite the presence of coronal and sagittal plane deformities and/or lateral mass abnormalities in the majority of cases. This system allowed for screw placement in the occiput, C1 lateral mass, C2 pars, C3-C7 lateral masses and upper thoracic pedicles. Early postoperative CT scanning confirmed satisfactory screw placement in all cases. Three patients experienced transient single-level radiculopathy, for an incidence of 1.4% per screw placed. Two patients developed wound seromas requiring evacuation. There were no infections or other wound healing problems. There were no examples of cord or vertebral artery injury, cerebrospinal fluid leak, screw malposition or back-out, loss of alignment or implant failure. When compared with plating techniques, screw-rod fixation appeared to offer several advantages. First, unlike plates, rods proved to be amenable to multiplanar contouring, which is often needed for deformities associated with cervical spondylosis. Second, lateral mass screw placement was more precise because it was not constrained by the hole spacing of the plate. Third, screw back-out and other types of implant failure were not seen. Fourth, the screw-rod system was more easily extended to the occiput and across the cervicothoracic junction. Fifth, the screw-rod system permitted the application of compression, distraction and reduction forces within the construct, to a greater extent than plate systems. The incidence of postoperative radiculopathy was similar to that seen with plate systems.
CONCLUSIONS: These data indicate that posterior cervical stabilization with polyaxial screw-rod fixation is a safe, straightforward technique that appears to offer some advantages over existing methods of fixation. Results appear to be durable at 1-year follow-up. Benefits are more significant with longer constructs, especially those extending to the occiput or crossing the cervicothoracic junction.

Entities:  

Mesh:

Year:  2003        PMID: 14609694

Source DB:  PubMed          Journal:  Spine J        ISSN: 1529-9430            Impact factor:   4.166


  30 in total

1.  Is intraoperative CT of posterior cervical spine instrumentation cost-effective and does it reduce complications?

Authors:  Andrew C Hecht; Steven M Koehler; Janelle C Laudone; Arthur Jenkins; Sheeraz Qureshi
Journal:  Clin Orthop Relat Res       Date:  2011-04       Impact factor: 4.176

2.  Does smoking influence fusion rates in posterior cervical arthrodesis with lateral mass instrumentation?

Authors:  Jason David Eubanks; Steven W Thorpe; Vinay K Cheruvu; Brett A Braly; James D Kang
Journal:  Clin Orthop Relat Res       Date:  2011-03       Impact factor: 4.176

3.  Comparative analysis of three different cervical lateral mass screw fixation techniques by complications and bicortical purchase : cadaveric study.

Authors:  Jin-Wook Baek; Dong-Mook Park; Dae-Hyun Kim
Journal:  J Korean Neurosurg Soc       Date:  2010-09-30

Review 4.  Cervical laminectomy and instrumented lateral mass fusion: techniques, pearls and pitfalls.

Authors:  Michael Mayer; Oliver Meier; Alexander Auffarth; Heiko Koller
Journal:  Eur Spine J       Date:  2013-05-29       Impact factor: 3.134

5.  Rod Migration to the Thoracic Subarachnoid Space after C1-2 Instrumentation: A Case Report and Literature Review.

Authors:  Seref Dogan; Elif Basaran Gundogdu; Mevlüt Özgür Taşkapılıoğlu; Ahmet Karaoglu
Journal:  Orthop Surg       Date:  2017-02       Impact factor: 2.071

Review 6.  Cervical spondylotic myelopathy: posterior decompression and pedicle screw fixation.

Authors:  Kuniyoshi Abumi
Journal:  Eur Spine J       Date:  2015-03-27       Impact factor: 3.134

7.  Lateral mass screw fixation in children.

Authors:  Daniel Hedequist; Mark Proctor; Timothy Hresko
Journal:  J Child Orthop       Date:  2010-03-19       Impact factor: 1.548

8.  Clinical experiences and usefulness of cervical posterior stabilization with polyaxial screw-rod system.

Authors:  In Chang Hwang; Dong-Ho Kang; Jong Woo Han; In Sung Park; Chul Hee Lee; Sun Young Park
Journal:  J Korean Neurosurg Soc       Date:  2007-10-20

9.  Comparative Analysis of Cervical Lateral Mass Screw Insertion among Three Techniques in the Korean Population by Quantitative Measurements with Reformatted 2D CT Scan Images: Clinical Research.

Authors:  Jae-Ik Cho; Dae-Hyun Kim
Journal:  J Korean Neurosurg Soc       Date:  2008-09-30

10.  Early results from posterior cervical fusion with a screw-rod system.

Authors:  Sang Hyun Kim; Dong Ah Shin; Seung Yi; Do Heum Yoon; Keung Nyun Kim; Hyun Chul Shin
Journal:  Yonsei Med J       Date:  2007-06-30       Impact factor: 2.759

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.