Removing a sewing needle from the pelvic cul-de-sac with an operative laparoscope.

P D Manganiello, J H Lee.   

Abstract

A case is reported of an unusual foreign body, a sewing needle, found in the pelvis beneath the peritoneum of the cul-de-sac and its successful removal via laparoscopy. The preoperative radiologic localization techniques are discussed. The use of the laparoscope for removing accessible foreign bodies can obviate the need for a more extensive surgical procedure.

Mesh:

Substances:

Year:  1978        PMID: 146089

Source DB:  PubMed          Journal:  J Reprod Med        ISSN: 0024-7758            Impact factor:   0.142


  1 in total

1.  Laparoscopic removal of a pancreatic foreign body.

Authors:  Cindy Wu; Eric S Hungness
Journal:  JSLS       Date:  2006 Oct-Dec       Impact factor: 2.172