Literature DB >> 14608892

Evaluation of the new multiplexed immunoassay, FIDIS, for simultaneous quantitative determination of antinuclear antibodies and comparison with conventional methods.

Anne-Marie Rouquette1, Chantal Desgruelles, Pascale Laroche.   

Abstract

Our study was done to evaluate the FIDIS Connective kit (Biomedical Diagnostics, Marne la Vallée, France) for simultaneous quantitative determination in the same sample of 9 antinuclear antibody specificities directed against double-stranded DNA, SSA, SSB, Sm, Sm/RNP, Scl-70, Jo-1, ribosome, and centromere B and to compare it with standardized commercial methods, enzyme immunoassay and immunofluorescence. FIDIS technology constitutes a new multiplexed method using the Luminex 100 system (Luminex, Austin, TX) based on the use of distinct color-coded particles and flow cytometric detection. Serum samples from people with diagnosed rheumatic diseases with well-identified markers of autoimmunity were tested by a retrospective study. Specificity was assessed by testing blood donors and potential biologic interfering samples. This first evaluation demonstrated the analytic performance of FIDIS technology. Concordances with routine methods were between 99.1% and 100.0% on 222 samples. FIDIS was reliable (coefficients of variation < 10%) and accurate (correlation coefficients with enzyme-linked immunosorbent assay between 0.90 and 0.97) in a large measure range.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14608892     DOI: 10.1309/GJHK-0D24-YDDX-W0NF

Source DB:  PubMed          Journal:  Am J Clin Pathol        ISSN: 0002-9173            Impact factor:   2.493


  7 in total

1.  Wash-free, electrochemical platform for the quantitative, multiplexed detection of specific antibodies.

Authors:  Ryan J White; Hannah M Kallewaard; Wen Hsieh; Adriana S Patterson; Jesse B Kasehagen; Kevin J Cash; Takanori Uzawa; H Tom Soh; Kevin W Plaxco
Journal:  Anal Chem       Date:  2012-01-03       Impact factor: 6.986

2.  Computer-assisted pattern recognition of autoantibody results.

Authors:  Steven R Binder; Mark C Genovese; Joan T Merrill; Robert I Morris; Allan L Metzger
Journal:  Clin Diagn Lab Immunol       Date:  2005-12

Review 3.  The U1-snRNP complex: structural properties relating to autoimmune pathogenesis in rheumatic diseases.

Authors:  Nicole H Kattah; Michael G Kattah; Paul J Utz
Journal:  Immunol Rev       Date:  2010-01       Impact factor: 12.988

4.  Evaluation of multiplexed fluorescent microsphere immunoassay for detection of autoantibodies to nuclear antigens.

Authors:  Thomas B Martins; Rufus Burlingame; Carlos A von Mühlen; Troy D Jaskowski; Christine M Litwin; Harry R Hill
Journal:  Clin Diagn Lab Immunol       Date:  2004-11

5.  Anti-Sm antibodies in the classification criteria of systemic lupus erythematosus.

Authors:  Joyce J B C van Beers; Marco W J Schreurs
Journal:  J Transl Autoimmun       Date:  2022-04-13

6.  Immunofluorescence microscopy is superior to fluorescent beads for detection of antinuclear antibody reactivity in systemic lupus erythematosus patients.

Authors:  Eduardo Bonilla; Lisa Francis; Fatme Allam; Meribeth Ogrinc; Hom Neupane; Paul E Phillips; Andras Perl
Journal:  Clin Immunol       Date:  2007-05-21       Impact factor: 3.969

Review 7.  Next-Generation Autoantibody Testing by Combination of Screening and Confirmation-the CytoBead® Technology.

Authors:  Mandy Sowa; Rico Hiemann; Peter Schierack; Dirk Reinhold; Karsten Conrad; Dirk Roggenbuck
Journal:  Clin Rev Allergy Immunol       Date:  2017-08       Impact factor: 8.667

  7 in total