Literature DB >> 14607496

Biomimetic and electrolytic calcium phosphate coatings on titanium alloy: physicochemical characteristics and cell attachment.

J Wang1, P Layrolle, M Stigter, K de Groot.   

Abstract

Biomimetically deposited octacalcium phosphate (OCP) and carbonate apatite (BCA) as well as electrolytically deposited carbonate apatite (ECA) were considered as promising alternatives to conventional plasma spraying hydroxyapatite. This study compared their physicochemical characteristics and cell attachment behavior. The physicochemical characteristics included scanning electron microscopy observation, X-ray diffraction analysis, Fourier transform infrared spectroscopy analysis, surface roughness, coating thickness, dissolution test and scratch test. Cell attachment tests included morphology observation with stereomicroscopy and scanning electron microscopy as well as cell number count with DNA content assay. The OCP coating had 100% crystallinity and was about 40 microm thick, composed of large plate-like crystals of 30 microm, with the lowest surface roughness (R(a)=2.33 microm). The BCA coating had 60% crystallinity and was approximately 30 microm in thickness, composed of small crystals of 1-2 microm in size, with the highest surface roughness (R(a)=4.83 microm). The ECA coating had intermediate characteristics, with 78% crystallinity, 45 microm thickness, crystals of 5-6 microm and an average roughness of 3.87 microm. All coatings could be seen by eyes dissolving quickly and completely into acidic simulated body fluid (simulated physiological solutions-SPS, pH 3.0) but slowly and incompletely into neutral SPS (pH 7.3). It was suggested that the main factor determining coating dissolution in acidic SPS was the solubility isotherm, while some other factors including crystallinity and crystal size joined to determine coating dissolution in neutral SPS. In regard to adhesive strength, results of scratch test showed the critical load at the first crack of coating (L(c1)) was tightly related to crystal size as well as their arrangement, while the critical load at the total delamination of coating (L(c2)) was also related to the coating thickness. The ECA coating had the highest values. Owing to higher dissolution rate and globular appearance, BCA coating demonstrated the best goat bone marrow stromal cells attachment at 1 day or 3 days, followed by OCP and ECA coating.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14607496     DOI: 10.1016/s0142-9612(03)00559-3

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  21 in total

1.  Osteoblast-like cell response to calcium phosphate coating chemistry and morphology on etched silicon surfaces.

Authors:  George A Burke; Chris J Rea; Fergal G Horgan; Marie Turkington; Adrian R Boyd; Brian J Meenan
Journal:  J Mater Sci Mater Med       Date:  2012-03       Impact factor: 3.896

2.  Preparation and antibiotic drug release of mineralized collagen coatings on titanium.

Authors:  Junjun Tu; Mengfei Yu; Yan Lu; Kui Cheng; Wenjian Weng; Jun Lin; Huiming Wang; Piyi Du; Gaorong Han
Journal:  J Mater Sci Mater Med       Date:  2012-06-06       Impact factor: 3.896

3.  The effect of mineral coating morphology on mesenchymal stem cell attachment and expansion.

Authors:  Siyoung Choi; William L Murphy
Journal:  J Mater Chem       Date:  2012-12-28

4.  Porous composite prosthetic pylon for integration with skin and bone.

Authors:  Mark Pitkin; Grigory Raykhtsaum; John Pilling; Oleg V Galibin; Mikhail V Protasov; Julie V Chihovskaya; Irina G Belyaeva; Miralda I Blinova; Natalia M Yudintseva; Igor L Potokin; George P Pinaev; Vladimir Moxson; Volodimir Duz
Journal:  J Rehabil Res Dev       Date:  2007

5.  Effect of fluoride on the morphology of calcium phosphate crystals grown on acid-etched human enamel.

Authors:  Y Fan; Z Sun; J Moradian-Oldak
Journal:  Caries Res       Date:  2009-03-24       Impact factor: 4.056

6.  Phase stability and biological property evaluation of plasma sprayed hydroxyapatite coatings for orthopedic and dental applications.

Authors:  Sahar Vahabzadeh; Mangal Roy; Amit Bandyopadhyay; Susmita Bose
Journal:  Acta Biomater       Date:  2015-01-28       Impact factor: 8.947

7.  Cell Cultivation on Porous Titanium Implants with Various Structures.

Authors:  M I Blinova; N M Yudintzeva; N S Nikolaenko; I L Potokin; G Raykhtsaum; M R Pitkin; G P Pinaev
Journal:  Cell tissue biol       Date:  2010

8.  Calcium orthophosphates (CaPO4): occurrence and properties.

Authors:  Sergey V Dorozhkin
Journal:  Prog Biomater       Date:  2015-11-19

9.  Formation of hydroxyapatite coating using novel chemo-biomimetic method.

Authors:  Jianhui Xie; Ben Li Luan
Journal:  J Mater Sci Mater Med       Date:  2008-05-02       Impact factor: 3.896

10.  ZrO(2)/hydroxyapatite coating on titanium by electrolytic deposition.

Authors:  Hsueh-Chuan Hsu; Shih-Ching Wu; Chih-Hsiung Yang; Wen-Fu Ho
Journal:  J Mater Sci Mater Med       Date:  2008-10-14       Impact factor: 3.896

View more