Literature DB >> 14606952

Cardiac output by Modelflow method from intra-arterial and fingertip pulse pressure profiles.

Marcel Azabji Kenfack1, Federic Lador, Marc Licker, Christian Moia, Enrico Tam, Carlo Capelli, Denis Morel, Guido Ferretti.   

Abstract

Modelflow, when applied to non-invasive fingertip pulse pressure recordings, is a poor predictor of cardiac output (Q, litre x min(-1)). The use of constants established from the aortic elastic characteristics, which differ from those of finger arteries, may introduce signal distortions, leading to errors in computing Q. We therefore hypothesized that peripheral recording of pulse pressure profiles undermines the measurement of Q with Modelflow, so we compared Modelflow beat-by-beat Q values obtained simultaneously non-invasively from the finger and invasively from the radial artery at rest and during exercise. Seven subjects (age, 24.0 +/- 2.9 years; weight, 81.2 +/- 12.6 kg) rested, then exercised at 50 and 100 W, carrying a catheter with a pressure head in the left radial artery and the photoplethysmographic cuff of a finger pressure device on the third and fourth fingers of the contralateral hand. Pulse pressure from both devices was recorded simultaneously and stored on a PC for subsequent Q computation. The mean values of systolic, diastolic and mean arterial pressure at rest and exercise steady state were significantly ( P < 0.05) lower from the finger than the intra-arterial catheter. The corresponding mean steady-state Q obtained from the finger (Qporta) was significantly ( P < 0.05) higher than that computed from the intra-arterial recordings (Qpia). The line relating beat-by-beat Qporta and Qpia was y =1.55 x -3.02 ( r2 = 0.640). The bias was 1.44 litre x min(-1) and the precision was 2.84 litre x min(-1). The slope of this line was significantly higher than 1, implying a systematic overestimate of Q by Qporta with respect to Qpia. Consistent with the tested hypothesis, these results demonstrate that pulse pressure profiles from the finger provide inaccurate absolute Q values with respect to the radial artery, and therefore cannot be used without correction with a calibration factor calculated previously by measuring Q with an independent method.

Entities:  

Mesh:

Year:  2004        PMID: 14606952     DOI: 10.1042/CS20030303

Source DB:  PubMed          Journal:  Clin Sci (Lond)        ISSN: 0143-5221            Impact factor:   6.124


  28 in total

1.  Cardiovascular time courses during prolonged immersed static apnoea.

Authors:  Renza Perini; Alberto Gheza; Christian Moia; Nicola Sponsiello; Guido Ferretti
Journal:  Eur J Appl Physiol       Date:  2010-05-11       Impact factor: 3.078

2.  Noninvasive cardiac output monitoring during exercise testing: Nexfin pulse contour analysis compared to an inert gas rebreathing method and respired gas analysis.

Authors:  Sebastiaan A Bartels; Wim J Stok; Rick Bezemer; Remco J Boksem; Jeroen van Goudoever; Thomas G V Cherpanath; Johannes J van Lieshout; Berend E Westerhof; John M Karemaker; Can Ince
Journal:  J Clin Monit Comput       Date:  2011-10-15       Impact factor: 2.502

3.  Central and peripheral hemodynamic responses to passive limb movement: the role of arousal.

Authors:  Massimo Venturelli; M Amann; J McDaniel; J D Trinity; A S Fjeldstad; R S Richardson
Journal:  Am J Physiol Heart Circ Physiol       Date:  2011-10-14       Impact factor: 4.733

4.  Nitric oxide and passive limb movement: a new approach to assess vascular function.

Authors:  Joel D Trinity; H Jonathan Groot; Gwenael Layec; Matthew J Rossman; Stephen J Ives; Sean Runnels; Ben Gmelch; Amber Bledsoe; Russell S Richardson
Journal:  J Physiol       Date:  2012-02-06       Impact factor: 5.182

5.  Dynamics of the RR-interval versus blood pressure relationship at exercise onset in humans.

Authors:  Aurélien Bringard; Alessandra Adami; Nazzareno Fagoni; Timothée Fontolliet; Frédéric Lador; Christian Moia; Enrico Tam; Guido Ferretti
Journal:  Eur J Appl Physiol       Date:  2017-02-25       Impact factor: 3.078

6.  Single passive leg movement-induced hyperemia: a simple vascular function assessment without a chronotropic response.

Authors:  Massimo Venturelli; Gwenael Layec; Joel Trinity; Corey R Hart; Ryan M Broxterman; Russell S Richardson
Journal:  J Appl Physiol (1985)       Date:  2016-11-10

7.  Wearable speckle plethysmography (SPG) for characterizing microvascular flow and resistance.

Authors:  Michael Ghijsen; Tyler B Rice; Bruce Yang; Sean M White; Bruce J Tromberg
Journal:  Biomed Opt Express       Date:  2018-07-30       Impact factor: 3.732

8.  Passive leg movement-induced hyperaemia with a spinal cord lesion: evidence of preserved vascular function.

Authors:  M Venturelli; M Amann; G Layec; J McDaniel; J D Trinity; A S Fjeldstad; S J Ives; G Yonnet; R S Richardson
Journal:  Acta Physiol (Oxf)       Date:  2013-11-05       Impact factor: 6.311

9.  Single passive leg movement assessment of vascular function: contribution of nitric oxide.

Authors:  Ryan M Broxterman; Joel D Trinity; Jayson R Gifford; Oh Sung Kwon; Andrew C Kithas; Jay R Hydren; Ashley D Nelson; David E Morgan; Jacob E Jessop; Amber D Bledsoe; Russell S Richardson
Journal:  J Appl Physiol (1985)       Date:  2017-08-31

10.  Evidence for unloading arterial baroreceptors during low levels of lower body negative pressure in humans.

Authors:  Qi Fu; Shigeki Shibata; Jeffrey L Hastings; Anand Prasad; M Dean Palmer; Benjamin D Levine
Journal:  Am J Physiol Heart Circ Physiol       Date:  2008-12-12       Impact factor: 4.733

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.