Scanning electron microscope observations of new and used nickel-titanium rotary files.

Satish B Alapati1, William A Brantley, Timothy A Svec, John M Powers, John C Mitchell.   

Abstract

The appearances of the tip sections of ProFile 0.04 taper and Lightspeed 25-mm long, ISO size 25, nickel-titanium rotary instruments were compared with a scanning electron microscope in the as-received condition and after one, three, and six simulated clinical uses to prepare mesial canals of extracted mandibular molars. For the used ProFile instruments, there was some flattening of the characteristic material rollover and minor apparent wear at the edges of the flutes, but there was little change in the tip regions of the used Lightspeed instruments. Deposits on the surfaces of the instruments were attributed to the manufacturing processes and the in vitro preparation of root canals in the extracted teeth. The simulated clinical use did not cause substantial changes in the regions of these two brands of rotary instruments that are involved in the clinical preparation of root canals.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14606793     DOI: 10.1097/00004770-200310000-00014

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  18 in total

1.  Mechanism of fracture of NiTi superelastic endodontic rotary instruments.

Authors:  Javier Gil; Elisa Rupérez; Eugenio Velasco; Conrado Aparicio; José María Manero
Journal:  J Mater Sci Mater Med       Date:  2018-08-07       Impact factor: 3.896

2.  Surface deformation of several nickel-titanium rotary instruments after removal of the root canal filling materials: a scanning electron microscope evaluation.

Authors:  Taha Özyürek; Ebru Özsezer Demiryürek
Journal:  Odontology       Date:  2019-09-17       Impact factor: 2.634

3.  Microstructural, microchemical, and mechanical changes associated with the clinical reuse of two nickel-titanium endodontic instruments.

Authors:  Felipe Augusto Restrepo-Restrepo; Viviana Andrea Holguín-Vásquez; Syldana Julieth Cañas-Jiménez; Paula Andrea Villa-Machado; Sara Ochoa-Soto; Claudia Patricia Ossa-Orozco; Sergio Iván Tobón-Arroyave
Journal:  Dent Res J (Isfahan)       Date:  2021-06-22

4.  Cyclic fatigue resistance of four nickel-titanium rotary instruments: a comparative study.

Authors:  Eugenio Pedullà; Gianluca Plotino; Nicola Maria Grande; Alfio Pappalardo; Ernesto Rapisarda
Journal:  Ann Stomatol (Roma)       Date:  2012-08-09

5.  The effects of different nickel-titanium instruments on dentinal microcrack formations during root canal preparation.

Authors:  Yakup Ustun; Tugrul Aslan; Burak Sagsen; Bertan Kesim
Journal:  Eur J Dent       Date:  2015 Jan-Mar

6.  An in vitro comparison of root canal system prepared with either hand or rotary instruments.

Authors:  Azza A Dafalla; Neamat Hassan Abubakr; Yahia E Ibrahim
Journal:  Iran Endod J       Date:  2010-11-15

7.  Geometric analysis of root canals prepared by single twisted file in three different operation modes.

Authors:  Xing-Chen Wu; Ya-Qin Zhu
Journal:  Eur J Dent       Date:  2014-10

8.  Canal preparation with nickel-titanium or stainless steel instruments without the risk of instrument fracture: preliminary observations.

Authors:  Ghassan Yared
Journal:  Restor Dent Endod       Date:  2014-11-13

9.  Assessment of the role of cross section on fatigue resistance of rotary files when used in reciprocation.

Authors:  Vadhana Sekar; Ranjith Kumar; Suresh Nandini; Suma Ballal; Natanasabapathy Velmurugan
Journal:  Eur J Dent       Date:  2016 Oct-Dec

10.  Incidence of apical crack formation and propagation during removal of root canal filling materials with different engine driven nickel-titanium instruments.

Authors:  Taha Özyürek; Vildan Tek; Koray Yılmaz; Gülşah Uslu
Journal:  Restor Dent Endod       Date:  2017-11-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.