Literature DB >> 14605726

[Angularly stable radius plate: progress in treatment of problematic distal radius fracture?].

K-H Thielke1, T Wagner, S Bartsch, V Echtermeyer.   

Abstract

Fractures of the distal radius represent one of the most common fractures and have high socioeconomic relevance. Using the volar approach to avoid the soft tissue problems associated with dorsal plating, we treated a consecutive series of 49 displaced intra-articular distal radius fractures with a new fixed-angle internal fixation device. According to the AO classification, there were 21 C1, 19 C2, and nine C3 fractures. A retrospective study was carried out to obtain the functional results after open reduction and plate osteosynthesis. Loss of correction between postoperative and follow-up radiography was 1 degrees in volar tilt and radial inclination. The radial shortening was 1 mm. Wrist motion at final follow-up examination had recovered to an average of 80% of that at the normal, contralateral site. Overall outcome according to the Gartland and Werley scales showed 35% excellent, 50% good, and 15% fair results. Using the Martini score, we obtained 85% excellent and good results. The DASH score represented high subjective satisfaction.

Entities:  

Mesh:

Year:  2003        PMID: 14605726     DOI: 10.1007/s00104-003-0718-3

Source DB:  PubMed          Journal:  Chirurg        ISSN: 0009-4722            Impact factor:   0.955


  22 in total

1.  The arthroscopic management of intra-articular distal radius fractures.

Authors:  A E Freeland; W B Geissler
Journal:  Hand Surg       Date:  2000-12

2.  Initial experience with the Forte plate for dorsally displaced distal radius fractures.

Authors:  V Finsen; T Aasheim
Journal:  Injury       Date:  2000-07       Impact factor: 2.586

3.  [Evaluation protocol for assessment of the wrist joint].

Authors:  A K Martini
Journal:  Handchir Mikrochir Plast Chir       Date:  1999-05       Impact factor: 1.018

4.  [Simultaneous management of multi-fragment distal radius fractures with palmar and dorsal approach].

Authors:  K Beyermann; K J Prommersberger
Journal:  Handchir Mikrochir Plast Chir       Date:  2000-11       Impact factor: 1.018

5.  [Correlation between surgical timing and incidence of complication in treatment of distal radius fracture].

Authors:  L Schütz
Journal:  Z Orthop Ihre Grenzgeb       Date:  2001 Sep-Oct

6.  Minor axial shortening of the radius affects outcome of Colles' fracture treatment.

Authors:  H T Aro; T Koivunen
Journal:  J Hand Surg Am       Date:  1991-05       Impact factor: 2.230

7.  Evaluation of healed Colles' fractures.

Authors:  J J GARTLAND; C W WERLEY
Journal:  J Bone Joint Surg Am       Date:  1951-10       Impact factor: 5.284

8.  Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report.

Authors:  Jorge L Orbay; Diego L Fernandez
Journal:  J Hand Surg Am       Date:  2002-03       Impact factor: 2.230

Review 9.  [The operative therapy of distal unstable radius fractures with dorsal and palmar plates. A retrospective study with respect to the DASH-score system].

Authors:  J Felderhoff; P Wiemer; J Dronsella; U Weber
Journal:  Orthopade       Date:  1999-10       Impact factor: 1.087

10.  [Results and analysis of poor results after conservative therapy of distal radius fracture].

Authors:  O Kwasny; G R Barisani; R Schabus; H Hertz
Journal:  Handchir Mikrochir Plast Chir       Date:  1991-09       Impact factor: 1.018

View more
  10 in total

1.  [Reliability and responsiveness of the German version of the Disabilities of the Arm, Shoulder and Hand questionnaire (DASH)].

Authors:  T Westphal
Journal:  Unfallchirurg       Date:  2007-06       Impact factor: 1.000

2.  Comparison of external fixation, locking and non-locking palmar plating for unstable distal radius fractures in the elderly.

Authors:  N Schmelzer-Schmied; P Wieloch; A K Martini; W Daecke
Journal:  Int Orthop       Date:  2008-01-12       Impact factor: 3.075

3.  Internal versus external fixation for unstable distal radius fractures: an up-to-date meta-analysis.

Authors:  Zhuang Cui; Jianhong Pan; Bin Yu; Kairui Zhang; Xiaolong Xiong
Journal:  Int Orthop       Date:  2011-06-23       Impact factor: 3.075

4.  [Volar locking plating for distal radial fractures. Is osteoporosis associated with poorer functional results and higher complications rates?].

Authors:  C Voigt; A Plesz; G Jensen; C Katthagen; H Lill
Journal:  Chirurg       Date:  2012-05       Impact factor: 0.955

5.  [Early results after palmar multi-axial plate osteosynthesis for treatment of distal radius fractures].

Authors:  T Geyer; K Hefele; J Gülke; F Gebhard; M Mentzel
Journal:  Unfallchirurg       Date:  2011-10       Impact factor: 1.000

Review 6.  [Trauma surgery in the elderly].

Authors:  H R Siebert; A Beck
Journal:  Chirurg       Date:  2005-02       Impact factor: 0.955

7.  [What advantages does volar plate fixation have over K-wire fixation for distal radius extension fractures in the elderly?].

Authors:  C Voigt; H Lill
Journal:  Unfallchirurg       Date:  2006-10       Impact factor: 1.000

8.  [Unidirectional versus multidirectional palmar locking osteosynthesis of unstable distal radius fractures: comparative analysis with LDR 2.4 mm versus 2.7 mm matrix-Smartlock].

Authors:  M Hakimi; P Jungbluth; S Gehrmann; J Nowak; J Windolf; M Wild
Journal:  Unfallchirurg       Date:  2010-03       Impact factor: 1.000

9.  [Quality of care after distal radius fracture in Germany. Results of a fracture register of 1,201 elderly patients].

Authors:  R Smektala; H G Endres; B Dasch; F Bonnaire; H J Trampisch; L Pientka
Journal:  Unfallchirurg       Date:  2009-01       Impact factor: 1.000

10.  Two peg spade plate for distal radius fractures: A novel technique.

Authors:  Sharad M Hardikar; Sreenivas Prakash; Madan S Hardikar; Rohit Kumar
Journal:  Indian J Orthop       Date:  2015 Sep-Oct       Impact factor: 1.251

  10 in total