Figure-of-eight method of measuring hand size: reliability and concurrent validity.

Geraldine L Pellecchia1.   

Abstract

The purpose of this study was to examine reliability and validity of a new method of measuring hand size in which a tape measure is wrapped around the hand in a figure-of-eight pattern. In the first experiment, two testers measured hand size in 60 individuals with no recent history of injury or surgery. Intraclass correlation coefficients of 0.99 and 0.97 indicated high intratester and intertester reliability. In the second experiment, concurrent validity of the figure-of-eight method was examined using volumetry as the criterion measure. Right hand size of 25 individuals with no recent history of injury or surgery was measured using the figure-of-eight method and volumetry. Pearson correlation coefficients of 0.94 indicated high concurrent validity. This study demonstrated reliability and validity of the figure-of-eight method of measuring hand size. To establish clinical usefulness, these findings must be replicated in individuals undergoing hand rehabilitation.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14605646     DOI: 10.1197/s0894-1130(03)00154-6

Source DB:  PubMed          Journal:  J Hand Ther        ISSN: 0894-1130            Impact factor:   1.950


  6 in total

1.  Prospective study of recovery from copperhead snake envenomation: an observational study.

Authors:  Eric J Lavonas; Charles J Gerardo
Journal:  BMC Emerg Med       Date:  2015-05-15

2.  Reliability of a new practical evaluation method for pitting edema based on the depth of the surface imprint.

Authors:  Haruki Kogo; Toshio Higashi; Jun Murata
Journal:  J Phys Ther Sci       Date:  2015-06-30

3.  Evaluation of kinesthetic sense and hand function in women with breast cancer-related lymphedema.

Authors:  Didem Karadibak; Tugba Yavuzsen
Journal:  J Phys Ther Sci       Date:  2015-06-30

4.  Validity of a New Quantitative Evaluation Method that Uses the Depth of the Surface Imprint as an Indicator for Pitting Edema.

Authors:  Haruki Kogo; Jun Murata; Shin Murata; Toshio Higashi
Journal:  PLoS One       Date:  2017-01-27       Impact factor: 3.240

5.  Effects of manual chest compression on expiratory flow bias during the positive end-expiratory pressure-zero end-expiratory pressure maneuver in patients on mechanical ventilation.

Authors:  Ana Carolina Otoni Oliveira; Daiane Menezes Lorena; Lívia Corrêa Gomes; Bianca Lorrane Reges Amaral; Márcia Souza Volpe
Journal:  J Bras Pneumol       Date:  2019-03-11       Impact factor: 2.624

6.  Pain reduction by inducing sensory-motor adaptation in Complex Regional Pain Syndrome (CRPS PRISMA): protocol for a double-blind randomized controlled trial.

Authors:  Monika Halicka; Axel D Vittersø; Michael J Proulx; Janet H Bultitude
Journal:  BMC Neurol       Date:  2020-02-19       Impact factor: 2.474

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.