Literature DB >> 14605034

The effect of successful heart transplant treatment of heart failure on central sleep apnea.

Darren R Mansfield1, Peter Solin, Teanau Roebuck, Peter Bergin, David M Kaye, Matthew T Naughton.   

Abstract

STUDY
OBJECTIVE: Central sleep apnea (CSA) associated with Cheyne-Stokes respiration in patients with congestive heart failure (CHF) is thought to be an acquired pattern of respiratory control instability related, at least in part, to elevated sympathetic nervous system activity. The effect of restoring heart function to normal with heart transplantation in patients with CHF and CSA has only been reported within weeks of the transplant and with varying results. The purpose of the study was to evaluate the impact of successful heart transplant on sympathetic nervous system activity and CSA severity in patients with CHF.
DESIGN: Controlled prospective trial.
SETTING: University hospital. PATIENTS: Twenty-two patients with CHF (13 patients with CSA, and 9 patients with no sleep-disordered breathing [SDB]). INTERVENTIONS AND MEASUREMENTS: Polysomnography, left ventricular ejection fraction (LVEF), and overnight urinary norepinephrine excretion (UNE) were measured before and > 6 months after successful heart transplantation.
RESULTS: In the CSA group, there was a fall in apnea-hypopnea index (AHI) [mean +/- SD, 28 +/- 15 to 7 +/- 6/h; p < 0.001] and UNE (48.1 +/- 30.9 to 6.1 +/- 4.8 nmol/mmol creatinine, p < 0.001) associated with normalization of LVEF (19.2 +/- 9.3% to 53.7 +/- 6.1%, p < 0.001) at 13.2 +/- 8.3 months following heart transplantation. Of the CSA group following transplantation, seven patients had no SDB (AHI < 5/h), three patients had persistent CSA (AHI, 12.3 +/- 0.9/h) and four patients acquired obstructive sleep apnea (OSA) [AHI, 11.2 +/- 7.4/h]. In comparison, none of the control group acquired CSA or OSA after transplantation.
CONCLUSIONS: We conclude that CSA may persist despite normalization of heart function and sympathetic nerve activity.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14605034     DOI: 10.1378/chest.124.5.1675

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  39 in total

Review 1.  Sleep in congestive heart failure.

Authors:  Bhavneesh Sharma; Robert Owens; Atul Malhotra
Journal:  Med Clin North Am       Date:  2010-05       Impact factor: 5.456

2.  Conversion from predominant central sleep apnea to obstructive sleep apnea following valvuloplasty in a patient with mitral regurgitation.

Authors:  Makiko Takahashi; Takatoshi Kasai; Tomotaka Dohi; Ken-ichi Maeno; Satoshi Kasagi; Fusae Kawana; Sugao Ishiwata; Koji Narui
Journal:  J Clin Sleep Med       Date:  2011-10-15       Impact factor: 4.062

3.  [Sleep apnea and heart failure].

Authors:  T Plenge; J Müller-Ehmsen
Journal:  Herz       Date:  2013-09       Impact factor: 1.443

Review 4.  Future of Sleep-Disordered Breathing Therapy Using a Mechanistic Approach.

Authors:  Rachel Jen; Michael A Grandner; Atul Malhotra
Journal:  Can J Cardiol       Date:  2015-02-14       Impact factor: 5.223

Review 5.  Altered breathing syndrome in heart failure: newer insights and treatment options.

Authors:  Yasuhiro Tomita; Takatoshi Kasai; Tomohiko Kisaka; Harry B Rossiter; Yasuki Kihara; Karlman Wasserman; Hiroyuki Daida
Journal:  Curr Heart Fail Rep       Date:  2015-04

Review 6.  Respiratory sleep disorders in patients with congestive heart failure.

Authors:  Matthew T Naughton
Journal:  J Thorac Dis       Date:  2015-08       Impact factor: 2.895

7.  Change in type of sleep-disordered breathing from predominant central to obstructive sleep apnea following coronary artery bypass grafting.

Authors:  Shoichiro Yatsu; Takatoshi Kasai; Hiroki Matsumoto; Azusa Murata; Takao Kato; Shoko Suda; Masaru Hiki; Nanako Shiroshita; Mitsue Kato; Fusae Kawana; Hiroyuki Daida
Journal:  J Cardiol Cases       Date:  2017-07-18

Review 8.  Cheyne-stokes respiration in patients with heart failure.

Authors:  Laila AlDabal; Ahmed S BaHammam
Journal:  Lung       Date:  2009-12-03       Impact factor: 2.584

9.  Resolution of sleep-disordered breathing with a biventricular assist device and recurrence after heart transplantation.

Authors:  Emmanuelle Vermes; Hortense Fonkoua; Matthias Kirsch; Thibaud Damy; Laurent Margarit; Marie-Line Hillion; Luc Hittinger; Marie-Pia d'Ortho
Journal:  J Clin Sleep Med       Date:  2009-06-15       Impact factor: 4.062

10.  Effect of continuous positive airway pressure on sleep structure in heart failure patients with central sleep apnea.

Authors:  Pimon Ruttanaumpawan; Alexander G Logan; John S Floras; T Douglas Bradley
Journal:  Sleep       Date:  2009-01       Impact factor: 5.849

View more