Literature DB >> 14597041

Relationship of optic disk topography and visual function in patients with large cup-to-disk ratios.

Steven L Mansberger1, Linda M Zangwill, Pamela A Sample, Dongseok Choi, Robert N Weinreb.   

Abstract

PURPOSE: To determine if topographic differences exist between large cup-to-disk ratio (C/D) eyes with standard achromatic automated perimetry (SAP) abnormalities and those with only short-wavelength automated perimetry (SWAP) abnormalities.
DESIGN: Cross-sectional study.
METHODS: The setting was a referral university-based clinical practice. We selected one eye of 72 patients with a vertical C/D of at least 0.8 by ophthalmoscopy. Patients performed SWAP, SAP, and confocal scanning laser ophthalmoscopy. We compared optic disk topography in eyes with and without visual field abnormalities and controlled for the influence of disk area.
RESULTS: Disk area was a confounder of many topographic measures. After controlling for disk area, eyes with abnormal SAP had differences in rim volume, cup shape, rim area, retinal nerve fiber layer thickness, and retinal nerve fiber layer cross-sectional area when compared with eyes with normal SAP (P <.05). Rim volume and rim area were different in the SWAP comparison (P <.05).
CONCLUSIONS: Investigators should control for disk area when evaluating topographic measures by confocal scanning laser ophthalmoscopy. In eyes with a large C/D, optic disk topography is more glaucomatous in eyes with SAP abnormalities than in those with only SWAP abnormalities. Eyes with large C/D and only SWAP abnormalities may have fewer glaucomatous optic disk changes than such eyes with SAP abnormalities. This indicates that SWAP is likely to correspond to abnormalities in optic disk topography at an earlier stage of glaucomatous optic neuropathy than SAP. Therefore, clinicians should consider SWAP testing in glaucoma suspects to detect glaucomatous visual field loss at an earlier stage of structural loss.

Entities:  

Mesh:

Year:  2003        PMID: 14597041     DOI: 10.1016/s0002-9394(03)00570-1

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  1 in total

1.  Comparing the full-threshold and Swedish interactive thresholding algorithms for short-wavelength automated perimetry.

Authors:  Minna Ng; Lyne Racette; John P Pascual; Jeffrey M Liebmann; Christopher A Girkin; Sarah L Lovell; Linda M Zangwill; Robert N Weinreb; Pamela A Sample
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-12-13       Impact factor: 4.799

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.