| Literature DB >> 14594674 |
P J Nyman1, G W Diachenko, G A Perfetti.
Abstract
A gas chromatography/mass spectrometry method for 3-MCPD in foods and food ingredients was modified for the determination of 1,3-DCP in soy and related sauces. The method was validated by using a blank soy sauce. The detection limit, quantitation limit and recoveries were determined, and identities were confirmed by mass spectrometry on the basis of analyses of test portions spiked with 1,3-DCP at 10, 25, 50 and 100 ng g(-1). The spiked test portions were quantitated by using an internal standard calibration curve. For the spiked test portions, the mean internal standard-corrected recovery for 1,3-DCP was 100% with a relative standard deviation of 1.32%. The limits of detection and quantitation were determined as 0.055 and 0.185 ng g(-1), respectively. The method also was compared with a headspace GC/MS method recently developed by the UK's Central Science Laboratory. Results from the method comparison showed that the recoveries for the spiked test portions, as well as the amounts of 1,3-DCP found in the retail products, were comparable.Entities:
Mesh:
Substances:
Year: 2003 PMID: 14594674 DOI: 10.1080/02652030310001603783
Source DB: PubMed Journal: Food Addit Contam ISSN: 0265-203X