Literature DB >> 14593246

Problems associated with collecting breath condensate for the measurement of exhaled hydrogen peroxide from neonates on respiratory support.

Fook-Choe Cheah1, Brian A Darlow, Christine C Winterbourn.   

Abstract

We developed a bedside method for collecting exhaled breath condensate (EBC) from neonates who were ventilated or receiving nasal continuous positive airway pressure (CPAP) and analyzed their EBC for hydrogen peroxide levels. A sufficient volume for analysis could be collected over 25-40 min from neonates on the ventilator and nasal CPAP (medians 5.3 and 2.7 ml, respectively). There was no significant difference between hydrogen peroxide levels from neonates on a ventilator or CPAP (median 0.28 vs. 0.38 microM, p = 0.06) and these were no different from a background with the ventilator or CPAP system alone (median for each 0.31 microM). The dilution of breath condensate by humidified gases plus the existence of background hydrogen peroxide resulted in this collecting setup being insufficiently sensitive to use for the detection of exhaled hydrogen peroxide in infants who were ventilated or on nasal CPAP. Copyright 2003 S. Karger AG, Basel

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14593246     DOI: 10.1159/000073644

Source DB:  PubMed          Journal:  Biol Neonate        ISSN: 0006-3126


  4 in total

1.  Association of hydrogen peroxide in exhaled breath condensates from infants with respiratory distress syndrome with the development of chronic lung disease.

Authors:  F-C Cheah; B A Darlow; C C Winterbourn
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2006-03       Impact factor: 5.747

Review 2.  Evolution of clinical and environmental health applications of exhaled breath research: Review of methods and instrumentation for gas-phase, condensate, and aerosols.

Authors:  M Ariel Geer Wallace; Joachim D Pleil
Journal:  Anal Chim Acta       Date:  2018-02-09       Impact factor: 6.558

Review 3.  Breath tests in respiratory and critical care medicine: from research to practice in current perspectives.

Authors:  Attapon Cheepsattayakorn; Ruangrong Cheepsattayakorn
Journal:  Biomed Res Int       Date:  2013-09-18       Impact factor: 3.411

4.  Exhaled breath condensate in intubated neonates--a window into the lung's glutathione status.

Authors:  Maria I Rosso; Susan Roark; Esther Taylor; XiaoDu Ping; Janine M Ward; Katherine Roche; Courtney McCracken; Lou Ann S Brown; Theresa W Gauthier
Journal:  Respir Res       Date:  2014-01-07
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.