Mohammed Al-Barbarawi1, Lali H S Sekhon.
Abstract
Thoracic disk herniation is a not uncommon pathology faced by the spinal surgeon. The management of massive intradural thoracic disk herniation with ventral cord compression is problematic both in terms of obtaining adequate decompression and ensuring no subsequent leakage of cerebrospinal fluid. A 54-year-old woman presented with a 10 year history of back pain and left leg pain. Over the past 6 months she experienced a progressive spastic paraparesis in both legs with recent urinary incontinence. A left anterolateral thoracotomy for excision of T8/9 thoracic disk protrusion was affected. A transdural decompression was performed with resection of the calcified dura and performance of a Gore-Tex duraplasty and pleuroplasty. A free muscle graft was placed in the intervening space and the chest drains were placed on non-suction. A spinal drain was maintained for 5 days. She made an excellent neurological recovery. Avoidance of cerebrospinal leakage is paramount when performing transthoracic approaches as negative intrapleural pressure can lead to persistence of leakage. This report documents a safe and reliable way to deal with massive intradural thoracic disk rupture with avoidance of subsequent spinal fluid leak.Entities:
Mesh:
Year: 2003 PMID: 14592628 DOI: 10.1016/j.jocn.2003.02.001