Literature DB >> 14592586

Assessment of fetal liver volume and umbilical venous volume flow in pregnancies complicated by insulin-dependent diabetes mellitus.

Simona M Boito1, Piet C Struijk, Nicolette T C Ursem, Theo Stijnen, Juriy W Wladimiroff.   

Abstract

OBJECTIVES: To determine fetal liver volume and its relation with umbilical venous volume flow and maternal glycosylated haemoglobin (HbA1c) in pregnancies complicated by diabetes mellitus type I.
DESIGN: A cross sectional matched control study. Obstetric out patient clinic, Erasmus MC-University Medical Centre, Rotterdam. POPULATION: Data from fetuses of diabetic women (n = 32; 18-36 weeks) were compared with data from normal controls (n = 32) matched for gestational age.
METHODS: Umbilical venous cross sectional area (mm(2)) and time-averaged velocity (mm/s Doppler) were determined for calculation of volume flow (mL/min) and flow per kilogram fetal weight (mL/min/kg). Umbilical artery pulsatility index was determined. Fetal liver volume measurements were obtained using a Voluson 530-D. MAIN OUTCOME MEASURES: Fetal liver volume, umbilical venous volume flow and downstream impedance.
RESULTS: A statistically significant difference between fetuses of diabetic women and normal controls was found for liver volume (mean [SD]: 45.9 [34.0] vs 38.3 [28.7] mL), abdominal circumference (22.2 [6.6] vs 21.3 [5.6] cm), estimated fetal weight (1162 [898] vs 1049 [765] g) and fetoplacental weight ratio (0.22 vs 0.19) and liver volume/estimated fetal weight ratio (4.13% [0.007] vs 3.62% [0.009]). Umbilical venous volume flow (mL/min) and umbilical artery pulsatility index were not essentially different between the two study groups, but umbilical venous volume flow per kilogram fetal weight was lower (P < 0.05) in the diabetes group (94.3 [26.1] mL/min kg) compared with normal controls (109.5 [28.0] mL/min/kg). A positive correlation existed between fetal liver volume and maternal HbA1c (P = 0.002).
CONCLUSIONS: Measurement of fetal liver volume by three-dimensional ultrasound may play a role in identifying fetal growth acceleration in diabetic pregnancies. Fetal liver volume increase is positively related to maternal HbA1c levels reflecting degree of maternal glycemic control. Fetal liver volume normalised for estimated fetal weight is significantly higher in the fetuses of diabetic women. In the present study, umbilical venous volume flow and fetoplacental downstream impedance are not different between diabetic and normal pregnancies.

Entities:  

Mesh:

Year:  2003        PMID: 14592586

Source DB:  PubMed          Journal:  BJOG        ISSN: 1470-0328            Impact factor:   6.531


  7 in total

1.  Predictive value of fetal hepatic biometry for birth weight and cord blood markers in gestational diabetes.

Authors:  J Garcia-Flores; M Cruceyra; M Cañamares; A Garicano; O Nieto; I Tamarit
Journal:  J Perinatol       Date:  2016-05-12       Impact factor: 2.521

Review 2.  Fetoplacental oxygen homeostasis in pregnancies with maternal diabetes mellitus and obesity.

Authors:  Gernot Desoye; Anthony M Carter
Journal:  Nat Rev Endocrinol       Date:  2022-07-28       Impact factor: 47.564

3.  Estimation of uterine volume: A comparison between Viewpoint and 3D ultrasound estimation in women undergoing laparoscopic hysterectomy.

Authors:  Ishwari Casikar; Max Mongelli; Shannon Reid; George Condous
Journal:  Australas J Ultrasound Med       Date:  2015-12-31

4.  Altered development of fetal liver perfusion in pregnancies with pregestational diabetes.

Authors:  Agnethe Lund; Cathrine Ebbing; Svein Rasmussen; Torvid Kiserud; Mark Hanson; Jörg Kessler
Journal:  PLoS One       Date:  2019-03-13       Impact factor: 3.240

5.  Volumetric Growth of the Liver in the Human Fetus: An Anatomical, Hydrostatic, and Statistical Study.

Authors:  Michał Szpinda; Monika Paruszewska-Achtel; Alina Woźniak; Celestyna Mila-Kierzenkowska; Gabriela Elminowska-Wenda; Małgorzata Dombek; Anna Szpinda; Mateusz Badura
Journal:  Biomed Res Int       Date:  2015-08-27       Impact factor: 3.411

6.  Assessing the accuracy and reliability of ultrasonographic three-dimensional parathyroid volume measurement in a patient with secondary hyperparathyroidism: a comparison with the two-dimensional conventional method.

Authors:  Sung-Hye You; Sang-Il Suh; In-Seon Ryoo; Gyu-Ri Son; Young-Hen Lee; Hyung Suk Seo; Nam Joon Lee; Hae Young Seol
Journal:  Ultrasonography       Date:  2016-06-08

7.  Assessing the consequences of gestational diabetes mellitus on offspring's cardiovascular health: MySweetHeart Cohort study protocol, Switzerland.

Authors:  Stefano Di Bernardo; Yvan Mivelaz; Adina Mihaela Epure; Yvan Vial; Umberto Simeoni; Pascal Bovet; Sandrine Estoppey Younes; Arnaud Chiolero; Nicole Sekarski
Journal:  BMJ Open       Date:  2017-11-14       Impact factor: 2.692

  7 in total