Literature DB >> 14588318

Segmental pedicle screw fixation or cross-links in multilevel lumbar constructs. a biomechanical analysis.

D S Brodke1, K N Bachus, R A Mohr, B K Nguyen.   

Abstract

BACKGROUND CONTEXT: The placement of segmental pedicle screws and cross-links in short segment posterior pedicle screw constructs has been shown to increase the construct stiffness in some planes. To date, no studies have looked at the contributions of segmental pedicle screw and cross-link placement in longer constructs.
PURPOSE: To evaluate the influence of segmental pedicle screw and/or cross-link placement on flexion/extension, lateral bending and axial torsion stiffness in two- and three-level posterior pedicle screw fixation constructs. STUDY DESIGN/
SETTING: An in vitro biomechanical analysis of two- and three-level posterior pedicle screw constructs with and without segmental fixation and/or cross-links was performed using calf lumbar spines. Stiffness of the constructs was compared.
METHODS: Six calf lumbar specimens were used to test stiffness in one-, two- and three-level posterior pedicle screw fixation constructs in 12 configurations. A custom-made, four-axis spine simulator applied pure cyclical (+/-5 Nm) flexion/extension, lateral bending and axial torsion moments at 0.1 Hz under a constant 50-N axial compressive load. The stiffness of each construct was calculated about each axis of rotation. Data were analyzed using nonparametric techniques with statistical significance determined at alpha less than .05.
RESULTS: The stiffness of the instrumented spines were significantly greater than the noninstrumented intact spines in all loading conditions for one-, two- and three-level constructs. There were no significant changes in flexion/extension stiffness with the addition of either the cross-links or the segmental pedicle screws. In lateral bending, the addition of segmental pedicle screws significantly increased the stiffness in the two- and three-level constructs. The addition of two cross-links increased lateral bending stiffness in the longer three-level constructs, with little change in the two-level constructs. In axial torsion, the progressive addition of cross-links showed a tendency toward increased stiffness in both the two- and three-level constructs. Segmental pedicle screws further increased torsional stiffness of the longer, three-level constructs.
CONCLUSIONS: As the use of segmental spinal instrumentation progresses from one to two and three levels, the contribution of cross-links and segmental pedicle screws to the overall construct stiffness increases.

Entities:  

Mesh:

Year:  2001        PMID: 14588318     DOI: 10.1016/s1529-9430(01)00116-4

Source DB:  PubMed          Journal:  Spine J        ISSN: 1529-9430            Impact factor:   4.166


  14 in total

1.  Biomechanical study of anterior spinal instrumentation configurations.

Authors:  Luc P Cloutier; Carl-Eric Aubin; Guy Grimard
Journal:  Eur Spine J       Date:  2007-01-05       Impact factor: 3.134

Review 2.  Management of burst fractures in the thoracolumbar spine.

Authors:  Mario Cahueque; Andrés Cobar; Carlos Zuñiga; Gustavo Caldera
Journal:  J Orthop       Date:  2016-06-28

Review 3.  Cross-links in posterior pedicle screw-rod instrumentation of the spine: a systematic review on mechanical, biomechanical, numerical and clinical studies.

Authors:  Frédéric Cornaz; Jonas Widmer; Jess Gerrit Snedeker; José Miguel Spirig; Mazda Farshad
Journal:  Eur Spine J       Date:  2020-10-03       Impact factor: 3.134

4.  Does addition of crosslink to pedicle-screw-based instrumentation impact the development of the spinal canal in children younger than 5 years of age?

Authors:  Zhong-hui Chen; Xi Chen; Ze-zhang Zhu; Bin Wang; Bang-ping Qian; Feng Zhu; Xu Sun; Yong Qiu
Journal:  Eur Spine J       Date:  2014-12-20       Impact factor: 3.134

5.  Cost-effectiveness of the treatment of traumatic thoracolumbar spine fractures: Nonsurgical or surgical therapy?

Authors:  Jan Siebenga; Michiel Jm Segers; Vincent Jm Leferink; Matthijs J Elzinga; Fred C Bakker; Henk-Jan Ten Duis; Pol M Rommens; Peter Patka
Journal:  Indian J Orthop       Date:  2007-10       Impact factor: 1.251

6.  Are the spines of calf, pig and sheep suitable models for pre-clinical implant tests?

Authors:  A Kettler; L Liakos; B Haegele; H-J Wilke
Journal:  Eur Spine J       Date:  2007-08-25       Impact factor: 3.134

7.  Contribution of the xenograft bone plate-screw system in lumbar transpedicular stabilization of dogs: an in-vitro study.

Authors:  Hakan Salci; Sani Sarigul; Seref Dogan; Huseyin Lekesiz; Resat Ozcan; O Sacit Gorgul; Kaya Aksoy
Journal:  J Vet Sci       Date:  2008-06       Impact factor: 1.672

8.  Three-dimensional printing technology for patient-matched instrument in treatment of cubitus varus deformity: A case report.

Authors:  Nithid Sri-Utenchai; Nachapan Pengrung; Korakod Srikong; Chedtha Puncreobutr; Boonrat Lohwongwatana; Paphon Sa-Ngasoongsong
Journal:  World J Orthop       Date:  2021-05-18

9.  [Biomechanical study of a ventral stand-alone cage for the lumbar spine with and without additional posterior fixation].

Authors:  U Vieweg; M Liner; M Lühn; A Neurauter; M Blauth; W Schmoelz
Journal:  Orthopade       Date:  2008-06       Impact factor: 1.004

10.  Staged Correction of Severe Thoracic Kyphosis in Patients with Multilevel Osteoporotic Vertebral Compression Fractures.

Authors:  Eyal Behrbalk; Ofir Uri; Yoram Folman; Marcus Rickert; Radek Kaiser; Bronek Maximilian Boszczyk
Journal:  Global Spine J       Date:  2015-12-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.