Literature DB >> 14583481

In vivo high resolution three-dimensional imaging of antigen-specific cytotoxic T-lymphocyte trafficking to tumors.

Moritz F Kircher1, Jennifer R Allport, Edward E Graves, Victoria Love, Lee Josephson, Andrew H Lichtman, Ralph Weissleder.   

Abstract

Magnetic resonance imaging (MRI) allows noninvasive and three-dimensional visualization of whole organisms over time, and, therefore, would be ideally suited to monitor cell trafficking in vivo. Until now, systemically injected cells had been difficult to visualize by MRI because of relatively inefficient labeling methods. We developed a novel, biocompatible, and physiologically inert nanoparticle (highly derivatized cross-linked iron oxide nanoparticle; CLIO-HD) for highly efficient intracellular labeling of a variety of cell types that now allows in vivo MRI tracking of systemically injected cells at near single-cell resolution. CD8+ cytotoxic T lymphocytes labeled with CLIO-HD were detectable via MRI with a detection threshold of 2 cells/voxel in vitro and approximately 3 cells/voxel in vivo in live mice. Using B16-OVA melanoma and CLIO-HD-labeled OVA-specific CD8+ T cells, we have demonstrated for the first time high resolution imaging of T-cell recruitment to intact tumors in vivo. We have revealed the extensive three-dimensional spatial heterogeneity of T-cell recruitment to target tumors and demonstrated a temporal regulation of T-cell recruitment within the tumor. Significantly, our data indicate that serial administrations of CD8+ T cells appear to home to different intratumoral locations, and may, therefore, provide a more effective treatment regimen than a single bolus administration. Together, these results demonstrate that CLIO-HD is uniquely suited for quantitative repetitive MRI of adoptively transferred cells and that this approach may be particularly useful for evaluating novel cell-based therapies in vivo.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14583481

Source DB:  PubMed          Journal:  Cancer Res        ISSN: 0008-5472            Impact factor:   12.701


  118 in total

1.  Complement Inhibitors Block Complement C3 Opsonization and Improve Targeting Selectivity of Nanoparticles in Blood.

Authors:  Hanmant Gaikwad; Yue Li; Geoffrey Gifford; Ernest Groman; Nirmal K Banda; Laura Saba; Robert Scheinman; Guankui Wang; Dmitri Simberg
Journal:  Bioconjug Chem       Date:  2020-06-29       Impact factor: 4.774

2.  Magnetic resonance imaging probes for labeling of chondrocyte cells.

Authors:  Gang Liu; Chunchao Xia; Zhiyong Wang; Fei Lv; Fabao Gao; Qiyong Gong; Bin Song; Hua Ai; Zhongwei Gu
Journal:  J Mater Sci Mater Med       Date:  2011-01-30       Impact factor: 3.896

3.  MRI detection of single particles for cellular imaging.

Authors:  Erik M Shapiro; Stanko Skrtic; Kathryn Sharer; Jonathan M Hill; Cynthia E Dunbar; Alan P Koretsky
Journal:  Proc Natl Acad Sci U S A       Date:  2004-07-15       Impact factor: 11.205

Review 4.  Molecular imaging for personalized cancer care.

Authors:  Moritz F Kircher; Hedvig Hricak; Steven M Larson
Journal:  Mol Oncol       Date:  2012-03-10       Impact factor: 6.603

Review 5.  Molecular body imaging: MR imaging, CT, and US. part I. principles.

Authors:  Moritz F Kircher; Jürgen K Willmann
Journal:  Radiology       Date:  2012-06       Impact factor: 11.105

6.  Bone marrow-derived lin(-)c-kit(+)Sca-1+ stem cells do not contribute to vasculogenesis in Lewis lung carcinoma.

Authors:  Vivek R Shinde Patil; Erik B Friedrich; Allison E Wolley; Robert E Gerszten; Jennifer R Allport; Ralph Weissleder
Journal:  Neoplasia       Date:  2005-03       Impact factor: 5.715

Review 7.  [Cell tracking. Principles and applications].

Authors:  J Grimm; M F Kircher; R Weissleder
Journal:  Radiologe       Date:  2007-01       Impact factor: 0.635

8.  Pace of macrophage recruitment during different stages of soft tissue infection: semi-quantitative evaluation by in vivo magnetic resonance imaging.

Authors:  Jin Seong Lee; Jin Young Sohn; Hyun-Don Jung; Sang-Tae Kim; Kyoung Geun Lee; Hee Jung Kang
Journal:  Eur Radiol       Date:  2008-05-06       Impact factor: 5.315

Review 9.  Detection and quantification of magnetically labeled cells by cellular MRI.

Authors:  Wei Liu; Joseph A Frank
Journal:  Eur J Radiol       Date:  2008-11-07       Impact factor: 3.528

10.  Conquering the dark side: colloidal iron oxide nanoparticles.

Authors:  Angana Senpan; Shelton D Caruthers; Ilsu Rhee; Nicholas A Mauro; Dipanjan Pan; Grace Hu; Michael J Scott; Ralph W Fuhrhop; Patrick J Gaffney; Samuel A Wickline; Gregory M Lanza
Journal:  ACS Nano       Date:  2009-12-22       Impact factor: 15.881

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.