Literature DB >> 14582658

Analysis of canine and feline haemograms using the VetScan HMT analyser.

E C Dewhurst1, E Crawford, S Cue, S Dodkin, A J German, K Papasouliotis.   

Abstract

The VetScan HMT is an impedance counter haematology analyser which produces a full blood count and three-part white blood cell differential. The aim of this study was to compare the results generated by the analyser with those obtained by standard methods used routinely in the authors' laboratory. Blood samples from 68 dogs and 59 cats were run on the VetScan HMT analyser and also subjected to reference methods, and the results obtained were compared. Correlation coefficients (feline/canine) were: 0.97/0.99 for haematocrit (Hct), 0.98/0.99 for haemoglobin (Hb), 0.81/0.98 for total white blood cells (WBC), and 0.89/0.97 for granulocyte and 0.65/0.93 for platelet counts. Coefficients for lymphocyte counts were 0.25/0.28 and for monocyte counts were 0.12/0.79. In conclusion, the VetScan HMT performed well on canine samples, showing excellent correlation for canine Hct, Hb, RBC, WBC, granulocyte and platelet counts. For feline samples, although there was excellent correlation for Hct, Hb and RBC, the WBC and three-part white blood cell differential and platelet count should be interpreted with caution as they can be unreliable.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14582658     DOI: 10.1111/j.1748-5827.2003.tb00103.x

Source DB:  PubMed          Journal:  J Small Anim Pract        ISSN: 0022-4510            Impact factor:   1.522


  3 in total

1.  Comparative clinical study of canine and feline total blood cell count results with seven in-clinic and two commercial laboratory hematology analyzers.

Authors:  Martina Becker; Andreas Moritz; Urs Giger
Journal:  Vet Clin Pathol       Date:  2008-12       Impact factor: 1.180

2.  Salivary Ferritin Changes in Patients with COVID-19.

Authors:  Lorena Franco-Martínez; José J Cerón; María R Vicente-Romero; Enrique Bernal; Alberto Torres Cantero; Fernando Tecles; Cristina Sánchez Resalt; Mónica Martínez; Asta Tvarijonaviciute; Silvia Martínez-Subiela
Journal:  Int J Environ Res Public Health       Date:  2021-12-21       Impact factor: 3.390

3.  Comparison of Measurements of 12 Analytes in Equine Blood Samples Using the In-Practice Falcor 350 and the Reference KoneLab 30i Analysers.

Authors:  K Papasouliotis; K V Tennant; S Dodkin; J Mason
Journal:  ISRN Vet Sci       Date:  2012-09-27