PURPOSE: The aim of this study was to evaluate the success rate of ITI implants with the SLA surface that were loaded after 6 weeks of healing. MATERIALS AND METHODS: In this prospective cohort study, a total of 104 implants were placed in posterior sites of 51 partially edentulous patients exhibiting bone densities of Class 1, 2, or 3. After a healing period of 6 weeks, all implants were functionally loaded with cemented crowns or fixed partial dentures. The patients were recalled at 3, 12, 24, and 36 months for clinical and radiographic examination. RESULTS: One implant failed to integrate during healing, and 1 implant was lost to follow-up and considered a dropout. The remaining 102 implants showed favorable clinical and radiographic findings and were considered successfully integrated at the 3-year examination. This resulted in a 3-year success rate of 99.03%. DISCUSSION: The peri-implant soft tissues were stable over time, as evidenced by no changes in the mean probing depths and the mean attachment levels during the follow-up period. None of the radiographs exhibited signs of continuous peri-implant radiolucency, which confirmed ankylotic stability of all 102 implants. The radiographic evaluation of the bone level at the implant indicated stability of the bone crest levels. CONCLUSION: The results of this prospective study demonstrated that early loading of ITI implants with the SLA surface after an unloaded healing period of 6 weeks provided successful tissue integration with high predictability, and that successful tissue integration was well maintained up to 3 years of follow-up in this study population.
PURPOSE: The aim of this study was to evaluate the success rate of ITI implants with the SLA surface that were loaded after 6 weeks of healing. MATERIALS AND METHODS: In this prospective cohort study, a total of 104 implants were placed in posterior sites of 51 partially edentulouspatients exhibiting bone densities of Class 1, 2, or 3. After a healing period of 6 weeks, all implants were functionally loaded with cemented crowns or fixed partial dentures. The patients were recalled at 3, 12, 24, and 36 months for clinical and radiographic examination. RESULTS: One implant failed to integrate during healing, and 1 implant was lost to follow-up and considered a dropout. The remaining 102 implants showed favorable clinical and radiographic findings and were considered successfully integrated at the 3-year examination. This resulted in a 3-year success rate of 99.03%. DISCUSSION: The peri-implant soft tissues were stable over time, as evidenced by no changes in the mean probing depths and the mean attachment levels during the follow-up period. None of the radiographs exhibited signs of continuous peri-implant radiolucency, which confirmed ankylotic stability of all 102 implants. The radiographic evaluation of the bone level at the implant indicated stability of the bone crest levels. CONCLUSION: The results of this prospective study demonstrated that early loading of ITI implants with the SLA surface after an unloaded healing period of 6 weeks provided successful tissue integration with high predictability, and that successful tissue integration was well maintained up to 3 years of follow-up in this study population.
Authors: Mehmet Kürkcü; Mehmet Emre Benlidayi; Serhat Ozsoy; Lütfiye Sevgi Ozyeğin; Faik Nuzhet Oktar; Cem Kurtoğlu Journal: J Mater Sci Mater Med Date: 2007-06-19 Impact factor: 3.896
Authors: Mingdeng Rong; Haibin Lu; Lei Wan; Xueyang Zhang; Xi Lin; Shaobing Li; Lei Zhou; Yingtao Lv; Yuan Su Journal: J Mater Sci Mater Med Date: 2018-03-30 Impact factor: 3.896