Literature DB >> 14578394

Topographical thickness of the epithelium and total cornea after overnight wear of reverse-geometry rigid contact lenses for myopia reduction.

Jianhua Wang1, Desmond Fonn, Trefford L Simpson, Luigina Sorbara, Richard Kort, Lyndon Jones.   

Abstract

PURPOSE: To investigate topographical thickness changes of the epithelium and total cornea measured with optical coherence tomography (OCT) after overnight wear of rigid gas-permeable lenses.
METHODS: Reverse geometry design CRT (Dk=100) rigid (test) lenses (Paragon Vision Sciences, Mesa, AZ) were randomly fitted on one eye of each of 20 neophyte subjects (mean age, 24.6 +/- 2.7 years) and the other eye was fitted with an alignment tricurve rigid lens of the same material (control). Epithelial and total corneal thickness was measured at intervals of 10 degrees across a 10-mm zone of the horizontal meridian of the cornea, before and after overnight wear. Refractive error was measured with an autorefractor. These measurements were repeated 20 and 60 minutes and 3, 6, and 12 hours after lens removal.
RESULTS: After one night of lens wear, myopia decreased in the test eye by 1.18 +/- 0.81 D, which was significantly different from baseline (P<0.001). No significant change was found in the control eye. Twelve hours after removal, two thirds of the myopic reduction was still present. Different topographical swelling patterns were induced by the two lens designs, with greatest swelling occurring in the center with the control lens and in the midperiphery with the test lenses (polynomial regression: P<0.005). Significantly greater central corneal swelling was found with the control lens than the test lens (6.9% +/- 3.1% vs. 4.9% +/- 2.0%, respectively, P=0.006). The effect on epithelial thickness differed between lenses and depended on both position and time (F(48,912)=2.3; P=0.000). Immediately after removal of the test lens, the central epithelium was 5.1% +/- 4.5% thinner than baseline, and all other locations (P<0.005 post hoc tests) and the epithelium in the midperiphery showed significant thickening (1.9% on the temporal side and 2.4% on the nasal side, both P<0.006 compared with the baseline). There were no significant changes in epithelial thickness with the control lens during the study period (post hoc tests: P>0.05).
CONCLUSIONS: The optical coherence tomograph is a sensitive instrument that can detect small changes in epithelial and corneal thickness across the entire cornea. Topographical thickness changes of the epithelium and total cornea induced by one night of reverse-geometry lens wear appear to be associated with the decrease of myopia.

Entities:  

Mesh:

Year:  2003        PMID: 14578394     DOI: 10.1167/iovs.03-0239

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  18 in total

1.  Repeated measurements of dynamic tear distribution on the ocular surface after instillation of artificial tears.

Authors:  Jianhua Wang; James Aquavella; Jayachandra Palakuru; Suk Chung
Journal:  Invest Ophthalmol Vis Sci       Date:  2006-08       Impact factor: 4.799

2.  Epithelial thickness in the normal cornea: three-dimensional display with Artemis very high-frequency digital ultrasound.

Authors:  Dan Z Reinstein; Timothy J Archer; Marine Gobbe; Ronald H Silverman; D Jackson Coleman
Journal:  J Refract Surg       Date:  2008-06       Impact factor: 3.573

3.  Topographic thickness of Bowman's layer determined by ultra-high resolution spectral domain-optical coherence tomography.

Authors:  Aizhu Tao; Jianhua Wang; Qi Chen; Meixiao Shen; Fan Lu; Sander R Dubovy; Mohamed Abou Shousha
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-06-01       Impact factor: 4.799

4.  Assessment of corneal epithelial thickness in dry eye patients.

Authors:  Xinhan Cui; Jiaxu Hong; Fei Wang; Sophie X Deng; Yujing Yang; Xiaoyu Zhu; Dan Wu; Yujin Zhao; Jianjiang Xu
Journal:  Optom Vis Sci       Date:  2014-12       Impact factor: 1.973

5.  A prospective interventional study of effect of accelerated orthokeratology on the corneal curvature and refraction among young adults with myopia.

Authors:  M A Khan; Ashutosh Gupta; T S Ahluwalia; P S Moulick; V S Gurunadh; Sandeep Gupta
Journal:  Med J Armed Forces India       Date:  2016-04-16

6.  Vertical and horizontal corneal epithelial thickness profiles determined by ultrahigh resolution optical coherence tomography.

Authors:  Chixin Du; Jianhua Wang; Lele Cui; Meixiao Shen; Yimin Yuan
Journal:  Cornea       Date:  2012-09       Impact factor: 2.651

7.  [Corneal changes after wearing orthokeratology contact lenses: an investigation using in vivo, confocal laser scanning microscopy].

Authors:  S Knappe; O Stachs; R Guthoff
Journal:  Ophthalmologe       Date:  2007-08       Impact factor: 1.059

8.  Correlation between epithelial thickness in normal corneas, untreated ectatic corneas, and ectatic corneas previously treated with CXL; is overall epithelial thickness a very early ectasia prognostic factor?

Authors:  Anastasios John Kanellopoulos; Ioannis M Aslanides; George Asimellis
Journal:  Clin Ophthalmol       Date:  2012-05-23

9.  Vertical and horizontal corneal epithelial thickness profile using ultra-high resolution and long scan depth optical coherence tomography.

Authors:  Shuangqing Wu; Aizhu Tao; Hong Jiang; Zhe Xu; Victor Perez; Jianhua Wang
Journal:  PLoS One       Date:  2014-05-20       Impact factor: 3.240

10.  New algorithm for corneal densitometry assessment based on anterior segment optical coherence tomography.

Authors:  Xiao Yu Wang; Jorge Peraza-Nieves; Tian Qiao Zhang; Anil Rahul Rachwani; Irene Blanco-Domínguez; Carlos Rocha de Lossada; Afredo Manuel Adán-Civiera
Journal:  Eye (Lond)       Date:  2021-08-02       Impact factor: 4.456

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.