Fast MRI-guided vacuum-assisted breast biopsy: initial experience.

Laura Liberman1, Elizabeth A Morris, D David Dershaw, Cynthia M Thornton, Kimberly J Van Zee, Lee K Tan.   

Abstract

OBJECTIVE: The purpose of this study was to evaluate a new method for performing MRI-guided vacuum-assisted breast biopsy in a study of lesions that had subsequent surgical excision. SUBJECTS AND METHODS. Twenty women scheduled for MRI-guided needle localization and surgical biopsy were prospectively entered in the study. MRI-guided biopsy was performed with a vacuum-assisted probe, followed by placement of a localizing clip, and then needle localization for surgical excision. Vacuum-assisted biopsy and surgical histology were correlated.
RESULTS: Vacuum-assisted biopsy was successfully performed in 19 (95%) of the 20 women. The median size of 27 MRI-detected lesions that had biopsy was 1.0 cm (range, 0.4-6.4 cm). Cancer was present in eight (30%) of 27 lesions and in six (32%) of 19 women; among these eight cancers, five were infiltrating and three were ductal carcinoma in situ (DCIS). Among these 27 lesions, histology was benign at vacuum-assisted biopsy and at surgery in 19 (70%), cancer at vacuum-assisted biopsy in six (22%), atypical ductal hyperplasia at vacuum-assisted biopsy and DCIS at surgery in one (4%), and benign at vacuum-assisted biopsy with surgery showing microscopic DCIS that was occult at MRI in one (4%). The median time to perform vacuum-assisted biopsy of a single lesion was 35 min (mean, 35 min; range, 24-48 min). Placement of a localizing clip, attempted in 26 lesions, was successful in 25 (96%) of 26, and the clip was retrieved on specimen radiography in 22 (96%) of 23. One complication occurred: a hematoma that resolved with compression.
CONCLUSION: MRI-guided vacuum-assisted biopsy is a fast, safe, and accurate alternative to surgical biopsy for breast lesions detected on MRI.

Entities:  

Mesh:

Year:  2003        PMID: 14573421     DOI: 10.2214/ajr.181.5.1811283

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  24 in total

1.  Outcome analysis of 9-gauge MRI-guided vacuum-assisted core needle breast biopsies.

Authors:  Gaiane M Rauch; Basak E Dogan; Taletha B Smith; Ping Liu; Wei T Yang
Journal:  AJR Am J Roentgenol       Date:  2012-02       Impact factor: 3.959

2.  Vacuum-assisted biopsies under MR guidance: results of 72 procedures.

Authors:  C Malhaire; C El Khoury; F Thibault; A Athanasiou; P Petrow; L Ollivier; A Tardivon
Journal:  Eur Radiol       Date:  2010-01-30       Impact factor: 5.315

3.  MR-guided stereotactic breast biopsy using a mixed ferromagnetic-nonmagnetic coaxial system with 12- to 18-gauge needles: clinical experience and long-term outcome.

Authors:  Elena Belloni; Pietro Panizza; Silvia Ravelli; Francesco De Cobelli; Simone Gusmini; Claudio Losio; Isabella Sassi; Gianluca Perseghin; Alessandro Del Maschio
Journal:  Radiol Med       Date:  2013-06-25       Impact factor: 3.469

4.  Contrast-enhanced MRI in breast cancer patients eligible for breast-conserving therapy: complementary value for subgroups of patients.

Authors:  Eline E Deurloo; William F A Klein Zeggelink; H Jelle Teertstra; Johannes L Peterse; Emiel J Th Rutgers; Sara H Muller; Harry Bartelink; Kenneth G A Gilhuijs
Journal:  Eur Radiol       Date:  2005-11-19       Impact factor: 5.315

5.  MR-guided vacuum-assisted breast biopsy with a handheld biopsy system: clinical experience and results in postinterventional MR mammography after 24 h.

Authors:  E A Hauth; H J Jaeger; J Lubnau; S Maderwald; F Otterbach; R Kimmig; M Forsting
Journal:  Eur Radiol       Date:  2007-07-03       Impact factor: 5.315

6.  MR imaging-guided 10-gauge vacuum-assisted breast biopsy: histological characterisation.

Authors:  T Perretta; C A Pistolese; F Bolacchi; E Cossu; V Fiaschetti; G Simonetti
Journal:  Radiol Med       Date:  2008-07-05       Impact factor: 3.469

7.  The risk of upgrade for atypical ductal hyperplasia detected on magnetic resonance imaging-guided biopsy: a study of 100 cases from four academic institutions.

Authors:  Thaer Khoury; Zaibo Li; Souzan Sanati; Mohamed M Desouki; Xiwei Chen; Dan Wang; Song Liu; Rouzan Karabakhtsian; Prasanna Kumar; Beatriu Reig
Journal:  Histopathology       Date:  2015-10-05       Impact factor: 5.087

8.  MRI-guided breast biopsy: outcomes and effect on patient management.

Authors:  Kelly S Myers; Ihab R Kamel; Katarzyna J Macura
Journal:  Clin Breast Cancer       Date:  2014-11-10       Impact factor: 3.225

Review 9.  State of the art of current modalities for the diagnosis of breast lesions.

Authors:  Cosimo Di Maggio
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-04-15       Impact factor: 9.236

10.  MRI-guided vacuum-assisted breast biopsy: a phantom and patient evaluation of targeting accuracy.

Authors:  Riham H El Khouli; Katarzyna J Macura; Peter B Barker; Laila M Elkady; Michael A Jacobs; Jens Vogel-Claussen; David A Bluemke
Journal:  J Magn Reson Imaging       Date:  2009-08       Impact factor: 4.813