Literature DB >> 14572057

Scanning electrochemical microscopy. 48. Hg/Pt hemispherical ultramicroelectrodes: fabrication and characterization.

Janine Mauzeroll1, Emily A Hueske, Allen J Bard.   

Abstract

Hg/Pt hemispherical ultramicroelectrodes (UMEs) (25-microm diameter) were prepared either by electrodeposition from a mercuric ion solution or by simple contact of the Pt disk to a hanging mercury drop electrode. The two methods produced equivalent tips. Optical inspection and electrochemical characterization of these Hg tips with methyl viologen, cobalt sepulchrate trichloride, and hexamineruthenium(III) chloride confirm the hemispherical nature of the UME. The scanning electrochemical microscopy approach curves for all three redox couples over a conductive substrate fit theoretical plots for hemispherical electrodes. The numerical solution of the diffusion equations for substrate generation-tip collection (SG-TC) transients for a finite Pt disk and Hg/Pt hemispherical UME are reported and compared to experimental results. A diffusion layer approximation is presented, and diffusion coefficients are extracted from the simulation. The SG-TC results reveal the enhanced sensitivity of hemispherical UME to radial diffusion.

Entities:  

Year:  2003        PMID: 14572057     DOI: 10.1021/ac034088l

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

1.  Droplet growth and transition to coalescence in confined geometries.

Authors:  Peter A Kottke; Audric Saillard; Andrei G Fedorov
Journal:  Langmuir       Date:  2006-06-20       Impact factor: 3.882

2.  Ultramicroelectrode Studies of Self-Terminated Nickel Electrodeposition and Nickel Hydroxide Formation upon Water Reduction.

Authors:  Nicole L Ritzert; Thomas P Moffat
Journal:  J Phys Chem C Nanomater Interfaces       Date:  2016-11-14       Impact factor: 4.126

3.  Scanning electrochemical microscopy of menadione-glutathione conjugate export from yeast cells.

Authors:  Janine Mauzeroll; Allen J Bard
Journal:  Proc Natl Acad Sci U S A       Date:  2004-05-17       Impact factor: 11.205

4.  Use of hg-electroplated-pt ultramicroelectrode for determining elemental sulphur in naphtha samples.

Authors:  Carlos Eduardo de Andrade; Flávia C de Souza; Daniella R Fernandes; Sérgio A S Machado; Eliane D'Elia
Journal:  J Anal Methods Chem       Date:  2012-04-03       Impact factor: 2.193

5.  Microstamped Petri dishes for scanning electrochemical microscopy analysis of arrays of microtissues.

Authors:  Adithya Sridhar; Hans L de Boer; Albert van den Berg; Séverine Le Gac
Journal:  PLoS One       Date:  2014-04-01       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.