Dan Shan1, Serge Cosnier, Christine Mousty.
Abstract
Electrochemical biosensors for phenol determination were developed based on the immobilization of polyphenol oxidase (PPO) within two different clay matrixes, one anionic (layered double hydroxide, LDH) and the other cationic (Laponite). The biosensor based on the enzyme immobilized in [Zn-Al-Cl] LDH shows greater sensitivity (7807 mA M(-1) cm(-2)) and maximum current (492 microA cm(-2)). Biosensor characteristics, such as Michaelis-Menten constant, recycling constant, activation energy, and permeability highlight the advantages of LDH matrixes to immobilize PPO. It appears that LDH provides a favorable environment to PPO activity. The best PPO/[Zn-Al-Cl] configuration was used to determine five different phenol derivatives reaching extremely sensitive detection limits (< or = 1 nM).Entities:
Mesh:
Substances:
Year: 2003 PMID: 14572056 DOI: 10.1021/ac030030v
Source DB: PubMed Journal: Anal Chem ISSN: 0003-2700 Impact factor: 6.986