Literature DB >> 14572055

Improving the detection limit of anion-selective electrodes: an iodide-selective membrane with a nanomolar detection limit.

Adam Malon1, Aleksandar Radu, Wei Qin, Yu Qin, Alan Ceresa, Magdalena Maj-Zurawska, Eric Bakker, Emö Pretsch.   

Abstract

The lower detection limit and the selectivity behavior of anion-selective electrodes (ISEs) are improved by using optimized inner solutions and membrane compositions. With a membrane based on the recently described ionophore [9]mercuracarborand-3, a detection limit of 2 x 10(-9) M has been achieved for iodide. Nevertheless, the improvements are less pronounced than in the case of cation ISEs. This is mainly due to the fact that so far no anion ISE is known with the extremely high selectivities of cation ISEs. If the membrane does not contain an ionophore, leaching of the ion exchanger from the membrane into the sample is also a relevant limiting factor except for ion exchangers of very high lipophilicity.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14572055     DOI: 10.1021/ac026454r

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  10 in total

1.  Approaches to Improving the Lower Detection Limit of Polymeric Membrane Ion-Selective Electrodes.

Authors:  Zsófia Szigeti; Tamás Vigassy; Eric Bakker; Ernö Pretsch
Journal:  Electroanalysis       Date:  2006-07-01       Impact factor: 3.223

2.  Improving the response behavior of Cd-selective polymeric membrane electrodes by incorporated lipophilic particles.

Authors:  Reto Thürer; Tamás Vigassy; Martina Hirayama; Ernö Pretsch
Journal:  Chem Analityczna       Date:  2006

3.  Potentiometric sensors for trace-level analysis.

Authors:  Eric Bakker; Ernö Pretsch
Journal:  Trends Analyt Chem       Date:  2005-03       Impact factor: 12.296

Review 4.  Modern potentiometry.

Authors:  Eric Bakker; Ernö Pretsch
Journal:  Angew Chem Int Ed Engl       Date:  2007       Impact factor: 15.336

5.  Solid contact potentiometric sensors for trace level measurements.

Authors:  Karin Y Chumbimuni-Torres; Nastassia Rubinova; Aleksandar Radu; Lauro T Kubota; Eric Bakker
Journal:  Anal Chem       Date:  2006-02-15       Impact factor: 6.986

6.  Ion-selective electrodes with unusual response functions: simultaneous formation of ionophore-primary ion complexes with different stoichiometries.

Authors:  Masafumi Miyake; Li D Chen; Gianluca Pozzi; Philippe Bühlmann
Journal:  Anal Chem       Date:  2011-12-22       Impact factor: 6.986

7.  Shifting the Measuring Range of Chloride Selective Electrodes and Optodes Based on the Anticrown Ionophore [9]Mercuracarborand-3 by the Addition of 1-Decanethiol.

Authors:  Aleksandar Radu; Eric Bakker
Journal:  Chem Analityczna       Date:  2005

8.  Subnanomolar Detection Limit Application of Ion-Selective Electrodes with Three-Dimensionally Ordered Macroporous (3DOM) Carbon Solid Contacts.

Authors:  Chun-Ze Lai; Marti M Joyer; Melissa A Fierke; Nicholas D Petkovich; Andreas Stein; Philippe Bühlmann
Journal:  J Solid State Electrochem       Date:  2009-01-01       Impact factor: 2.647

9.  Stimuli responsive ionogels for sensing applications-an overview.

Authors:  Andrew Kavanagh; Robert Byrne; Dermot Diamond; Kevin J Fraser
Journal:  Membranes (Basel)       Date:  2012-02-07

10.  Influence of Ionic Liquids on the Selectivity of Ion Exchange-Based Polymer Membrane Sensing Layers.

Authors:  Lukasz Mendecki; Nicole Callan; Meghan Ahern; Benjamin Schazmann; Aleksandar Radu
Journal:  Sensors (Basel)       Date:  2016-07-16       Impact factor: 3.576

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.