Literature DB >> 14571938

Alignment of trans-tibial prostheses based on roll-over shape principles.

A H Hansen1, M R Meier, M Sam, D S Childress, M L Edwards.   

Abstract

The authors examined the roll-over shape alignment hypothesis, which states that prosthetic feet are aligned by matching their roll-over shapes with an "ideal" shape. The "ideal" shape was considered to be the roll-over shape of the able-bodied foot-ankle system. An alignment algorithm and computational alignment system were developed to set trans-tibial alignments based on this hypothesis. Three prosthetic feet with considerably different roll-over shapes were either aligned using the alignment system or not aligned (i.e. used previous foot's alignment), and then were aligned by a team of prosthetists. No significant differences were found between roll-over shapes aligned by the computational alignment system and those based on standard clinical techniques (p = 0.944). Significant differences were found between the "no alignment" shapes and the prosthetist alignment shapes (p = 0.006), and between the "no alignment" shapes and the computational alignment system shapes (p = 0.024). The results of the experiment support the hypothesis that the goal of alignment is to match the prosthetic foot's roll-over shape, as closely as possible, with an "ideal" shape. The hypothesis is also supported by its ability to explain the results of previous studies. Using an "ideal" roll-over shape or surface as a goal for prosthetic alignment could lead to a priori alignment, eliminating the need for alignment hardware in some cases. Being able to build the alignment into a prosthesis without special hardware could be beneficial in low-income countries and in the fabrication of lightweight prostheses for the elderly.

Mesh:

Year:  2003        PMID: 14571938     DOI: 10.1080/03093640308726664

Source DB:  PubMed          Journal:  Prosthet Orthot Int        ISSN: 0309-3646            Impact factor:   1.895


  7 in total

1.  Effective rocker shapes used by able-bodied persons for walking and fore-aft swaying: implications for design of ankle-foot prostheses.

Authors:  Andrew H Hansen; Charles C Wang
Journal:  Gait Posture       Date:  2010-05-14       Impact factor: 2.840

2.  Sensitivity of biomechanical outcomes to independent variations of hindfoot and forefoot stiffness in foot prostheses.

Authors:  Peter Gabriel Adamczyk; Michelle Roland; Michael E Hahn
Journal:  Hum Mov Sci       Date:  2017-05-09       Impact factor: 2.161

3.  Response of able-bodied persons to changes in shoe rocker radius during walking: changes in ankle kinematics to maintain a consistent roll-over shape.

Authors:  Charles C Wang; Andrew H Hansen
Journal:  J Biomech       Date:  2010-05-18       Impact factor: 2.712

Review 4.  How a diverse research ecosystem has generated new rehabilitation technologies: Review of NIDILRR's Rehabilitation Engineering Research Centers.

Authors:  David J Reinkensmeyer; Sarah Blackstone; Cathy Bodine; John Brabyn; David Brienza; Kevin Caves; Frank DeRuyter; Edmund Durfee; Stefania Fatone; Geoff Fernie; Steven Gard; Patricia Karg; Todd A Kuiken; Gerald F Harris; Mike Jones; Yue Li; Jordana Maisel; Michael McCue; Michelle A Meade; Helena Mitchell; Tracy L Mitzner; James L Patton; Philip S Requejo; James H Rimmer; Wendy A Rogers; W Zev Rymer; Jon A Sanford; Lawrence Schneider; Levin Sliker; Stephen Sprigle; Aaron Steinfeld; Edward Steinfeld; Gregg Vanderheiden; Carolee Winstein; Li-Qun Zhang; Thomas Corfman
Journal:  J Neuroeng Rehabil       Date:  2017-11-06       Impact factor: 4.262

5.  Effect of prosthetic ankle units on roll-over shape characteristics during walking in persons with bilateral transtibial amputations.

Authors:  Steven A Gard; Po-Fu Su; Robert D Lipschutz; Andrew H Hansen
Journal:  J Rehabil Res Dev       Date:  2011

6.  Energetic consequences of using a prosthesis with adaptive ankle motion during slope walking in persons with a transtibial amputation.

Authors:  Benjamin J Darter; Jason M Wilken
Journal:  Prosthet Orthot Int       Date:  2013-03-22       Impact factor: 1.895

7.  Mechanical and dynamic characterization of prosthetic feet for high activity users during weighted and unweighted walking.

Authors:  Sara R Koehler-McNicholas; Eric A Nickel; Kyle Barrons; Kathryn E Blaharski; Clifford A Dellamano; Samuel F Ray; Barri L Schnall; Brad D Hendershot; Andrew H Hansen
Journal:  PLoS One       Date:  2018-09-12       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.