Literature DB >> 14571328

Balloon sensors for the manometric recording of the pharyngoesophageal tract: an experimental study.

Sandro Mattioli1, Marialuisa Lugaresi, Romano Zannoli, Stefano Brusori, Franco d'Ovidio.   

Abstract

The goal of our study was to investigate manometric balloon sensors of original conception in order to overcome the limitations of perfused and solid-state sensors in the assessment of the pharyngoesophageal motility abnormalities. A standard perfused probe for esophageal manometry was modified by applying fluid-filled floppy balloons 0.5-, 1-, and 2.5-cm long. The balloon sensor probe was tested at the bench with regard to the response to the applied pressures, the frequency-response curve, and the behavior during propagation of the peristaltic waves in an esophageal model. The physical properties of the balloon sensors proved to be adequate for pharyngoesophageal motility studies. The static response of the balloon probe to the applied pressures was linear. For the frequency-response curve, the upper cutoff frequency (A=1/square root of 2) was 23 Hz, resonance frequency was 16 Hz, and resonance amplification was 1.6. No statistically significant differences were observed between balloon sensors of different length with regard to amplitude and duration of recorded peristaltic waves (p>0.05). In conclusion, the balloon probe has the physical and technical characteristics required for the study of swallowing disorders.

Entities:  

Mesh:

Year:  2003        PMID: 14571328     DOI: 10.1007/s00455-003-0009-7

Source DB:  PubMed          Journal:  Dysphagia        ISSN: 0179-051X            Impact factor:   3.438


  7 in total

1.  The pressure profile of the gastroesophageal sphincter in man: an improved method of detection.

Authors:  C F CODE; J F SCHLEGEL
Journal:  Proc Staff Meet Mayo Clin       Date:  1958-08-06

2.  [Monitoring esophageal pressure: comparison of various methods and a unique solution].

Authors:  S Mattioli; R Zannoli; V Felice; V Pilotti; A Lazzari; M P Di Simone; A Raspadori; G Gozzetti
Journal:  Minerva Chir       Date:  1991-04-15       Impact factor: 1.000

3.  A new technique for continuous sphincter pressure measurement.

Authors:  J Dent
Journal:  Gastroenterology       Date:  1976-08       Impact factor: 22.682

4.  Sleeve device functions as a Starling resistor to record sphincter pressure.

Authors:  J H Linehan; J Dent; W J Dodds; W J Hogan
Journal:  Am J Physiol       Date:  1985-02

5.  Monitoring the lower oesophageal sphincter: sphinctometer or sleeve?

Authors:  N J Trudgill; S A Riley
Journal:  Neurogastroenterol Motil       Date:  1999-06       Impact factor: 3.598

Review 6.  American Gastroenterological Association technical review on the clinical use of esophageal manometry.

Authors:  P J Kahrilas; R E Clouse; W J Hogan
Journal:  Gastroenterology       Date:  1994-12       Impact factor: 22.682

7.  The sphinctometer: a new device for measurement of lower oesophageal sphincter function.

Authors:  D C Gotley; C P Barham; R Miller; R Arnold; D Alderson
Journal:  Br J Surg       Date:  1991-08       Impact factor: 6.939

  7 in total
  2 in total

1.  Pharyngoesophageal manometry with an original balloon sensor probe for the study of oropharyngeal dysphagia.

Authors:  Sandro Mattioli; Marialuisa Lugaresi; Romano Zannoli; Stefano Brusori; Franco d'Ovidio; Laura Braccaioli
Journal:  Dysphagia       Date:  2003       Impact factor: 3.438

2.  Monitoring of pharyngeal and upper esophageal sphincter activity with an arterial dilation balloon catheter.

Authors:  Mats Lindén; Sture Högosta; Tomas Norlander
Journal:  Dysphagia       Date:  2007-04       Impact factor: 3.438

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.