Literature DB >> 14570325

Determination of polar organophosphorus pesticides in vegetables and fruits using liquid chromatography with tandem mass spectrometry: selection of extraction solvent.

Hans G J Mol1, Ruud C J van Dam, Odile M Steijger.   

Abstract

A method based on liquid chromatography (LC)-mass spectrometry (MS)/MS was developed for sensitive determination of a number of less gas chromatography (GC)-amenable organophosphorus pesticides (OPs; acephate, methamidophos, monocrotophos, omethoate, oxydemeton-methyl and vamidothion) in cabbage and grapes. For extraction, several solvents were evaluated with respect to the possibility of direct injection, matrix-induced suppression or enhancement of response, and extraction efficiency. Overall, ethyl acetate was the most favourable solvent for extraction, although a solvent switch was required. For some pesticide/matrix combinations, reconstitution of the residue after evaporation required special attention. Extracts were analysed on a C18 column with polar endcapping. The pesticides were ionised using atmospheric pressure chemical ionisation on a tandem mass spectrometer in multiple reaction monitoring mode. The final method is straightforward and involves extraction with ethyl acetate and a solvent switch to 0.1% acetic acid/water without further cleanup. The method was validated at the 0.01 and 0.5 mg/kg level, for both cabbage and grapes. Recoveries were between 80 and 101% with R.S.D. < 11% (n = 5). The limit of quantification was 0.01 mg/kg and limits of detection were between 0.001 and 0.004 mg/kg.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14570325     DOI: 10.1016/s0021-9673(03)01209-3

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  3 in total

1.  Evaluation of the safe use and dietary risk of beta-cypermethrin, pyriproxyfen, avermectin, diflubenzuron and chlorothalonil in button mushroom.

Authors:  Pengqiang Du; Xiaohu Wu; Hairong He; Ying Zhang; Jun Xu; Fengshou Dong; Yongquan Zheng; Xingang Liu
Journal:  Sci Rep       Date:  2017-08-18       Impact factor: 4.379

2.  A built-in self-calibrating luminescence sensor based on RhB@Zr-MOF for detection of cations, nitro explosives and pesticides.

Authors:  Liu Yang; Yu-Long Liu; Cheng-Guo Liu; Ying Fu; Fei Ye
Journal:  RSC Adv       Date:  2020-05-20       Impact factor: 4.036

3.  Modification and re-validation of the ethyl acetate-based multi-residue method for pesticides in produce.

Authors:  Hans G J Mol; Astrid Rooseboom; Ruud van Dam; Marleen Roding; Karin Arondeus; Suryati Sunarto
Journal:  Anal Bioanal Chem       Date:  2007-06-12       Impact factor: 4.142

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.