Literature DB >> 14570178

Picoamperometric detection of glucose at ultrasmall platinum-based biosensors: preparation and characterization.

Sabahudin Hrapovic1, John H T Luong.   

Abstract

A simple method is described for the construction of a glucose biosensor with good reproducibility. After electrochemical etching, the sensing tip of an etched platinum microelectrode was insulated using a synthetic rubber dip coating. The insulating layer was then heat-cured, leading to a small exposed area at the very end of the etched Pt tip, as confirmed by scanning electron microscopy. Phenol and 2-allylphenol were electropolymerized to form an extra insulating layer that effectively retained glucose oxidase (GOX) on the sensing tip of the electrode. On the basis of cyclic voltammetry measurements, the apparent radius of the biosensor tip was estimated to be between 10 and 500 nm, depending on GOX loading. With operational and storage stabilities over 3 weeks, the glucose biosensor prepared using optimal GOX concentration (10 mg/mL) exhibited a picoamperometric current response within approximately 2 s and a detection limit of 20 microM with excellent reproducibility.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14570178     DOI: 10.1021/ac026438u

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

1.  Rational design of binder-free noble metal/metal oxide arrays with nanocauliflower structure for wide linear range nonenzymatic glucose detection.

Authors:  Zhenzhen Li; Yanmei Xin; Zhonghai Zhang; Hongjun Wu; Peng Wang
Journal:  Sci Rep       Date:  2015-06-12       Impact factor: 4.379

Review 2.  CMOS Electrochemical Instrumentation for Biosensor Microsystems: A Review.

Authors:  Haitao Li; Xiaowen Liu; Lin Li; Xiaoyi Mu; Roman Genov; Andrew J Mason
Journal:  Sensors (Basel)       Date:  2016-12-31       Impact factor: 3.576

3.  On-Chip Glucose Detection Based on Glucose Oxidase Immobilized on a Platinum-Modified, Gold Microband Electrode.

Authors:  Julia Madden; Colm Barrett; Fathima R Laffir; Michael Thompson; Paul Galvin; Alan O' Riordan
Journal:  Biosensors (Basel)       Date:  2021-07-25

4.  Sensitive electrochemical nonenzymatic glucose sensing based on anodized CuO nanowires on three-dimensional porous copper foam.

Authors:  Zhenzhen Li; Yan Chen; Yanmei Xin; Zhonghai Zhang
Journal:  Sci Rep       Date:  2015-11-02       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.