Literature DB >> 14568417

Increased release of gentamicin from acrylic bone cements under influence of low-frequency ultrasound.

Johannes G E Hendriks1, Geert T Ensing, Jim R van Horn, Jaap Lubbers, Henny C van der Mei, Henk J Busscher.   

Abstract

The release profile of antibiotics from antibiotic-loaded bone cement, used to prevent infections in total joint arthroplasty, is neither ideal nor complete. Ultrasound has been used to allow drugs to cross otherwise impermeable barriers. The aim of this study was to establish a possible effect of ultrasound on antibiotic release from bone cements. Samples were made of three commercially available gentamicin-loaded bone cements. Part of the samples was allowed to release gentamicin for 3 weeks before insonation. An insonation device produced an ultrasound field with a time average acoustic intensity of 167 mW/cm2 at a frequency of 46.5 kHz. The samples were exposed to the ultrasound field or not exposed to it as a control. The amount of gentamicin released was measured by fluorescence polarization immunoassay. There was a limited increase of gentamicin release with application of ultrasound in fresh samples but not in the samples that had been allowed to release gentamicin. For fresh samples, a linear regression model showed that this ultrasound effect was statistically significant. The mechanism behind these observations is not clear, but it is suggested that microstreaming or localized temperature rises may be involved.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14568417     DOI: 10.1016/s0168-3659(03)00361-4

Source DB:  PubMed          Journal:  J Control Release        ISSN: 0168-3659            Impact factor:   9.776


  11 in total

1.  Effect of delayed pulsed-wave ultrasound on local pharmacokinetics and pharmacodynamics of vancomycin-loaded acrylic bone cement in vivo.

Authors:  Xun-Zi Cai; Shi-Gui Yan; Hao-Bo Wu; Rong-Xin He; Xue-Song Dai; Hai-Xiang Chen; Rui-Jian Yan; Xin-Hua Zhao
Journal:  Antimicrob Agents Chemother       Date:  2007-07-09       Impact factor: 5.191

2.  Antimicrobial-Loaded Bone Cement Does Not Negatively Influence Sonicate Fluid Culture Positivity for Diagnosis of Prosthetic Joint Infection.

Authors:  Kyung-Hwa Park; Kerryl E Greenwood-Quaintance; Arlen D Hanssen; Matthew P Abdel; Robin Patel
Journal:  J Clin Microbiol       Date:  2016-03-30       Impact factor: 5.948

3.  Mesoporous silica nanoparticle-functionalized poly(methyl methacrylate)-based bone cement for effective antibiotics delivery.

Authors:  Shou-Cang Shen; Wai Kiong Ng; Zhilong Shi; Leonard Chia; Koon Gee Neoh; Reginald Beng Hee Tan
Journal:  J Mater Sci Mater Med       Date:  2011-07-24       Impact factor: 3.896

4.  Effect of pulsed ultrasound in combination with gentamicin on bacterial viability in biofilms on bone cements in vivo.

Authors:  G T Ensing; B L Roeder; J L Nelson; J R van Horn; H C van der Mei; H J Busscher; W G Pitt
Journal:  J Appl Microbiol       Date:  2005       Impact factor: 3.772

5.  In vitro and in vivo evaluation of vancomycin-loaded PMMA cement in combination with ultrasound and microbubbles-mediated ultrasound.

Authors:  Tiao Lin; Xun-Zi Cai; Ming-Min Shi; Zhi-Min Ying; Bin Hu; Chen-He Zhou; Wei Wang; Zhong-Li Shi; Shi-Gui Yan
Journal:  Biomed Res Int       Date:  2015-01-06       Impact factor: 3.411

6.  Effect of Sonication on the Elution of Antibiotics from Polymethyl Methacrylate (PMMA).

Authors:  Anne Kummer; Ulrika Furustrand Tafin; Olivier Borens
Journal:  J Bone Jt Infect       Date:  2017-11-13

7.  Influence of Sonication on Bacterial Regrowth from Antibiotic Loaded PMMA Scaffolds - An In-vitro Study.

Authors:  Martin Clauss; Esther Laschkolnig; Susanne Graf; Klaus-Dieter Kühn
Journal:  J Bone Jt Infect       Date:  2017-11-17

Review 8.  A Review of the Combination Therapy of Low Frequency Ultrasound with Antibiotics.

Authors:  Yun Cai; Jin Wang; Xu Liu; Rui Wang; Lei Xia
Journal:  Biomed Res Int       Date:  2017-10-16       Impact factor: 3.411

9.  Effect of Low-Frequency Pulsed Ultrasound on Drug Delivery, Antibacterial Efficacy, and Bone Cement Degradation in Vancomycin-Loaded Calcium Phosphate Cement.

Authors:  Mingmin Shi; Lei Chen; Yangxin Wang; Wei Wang; Shigui Yan
Journal:  Med Sci Monit       Date:  2018-02-08

10.  Diagnosis of Persistent Infection in Prosthetic Two-Stage Exchange: Evaluation of the Effect of Sonication on Antibiotic Release from Bone Cement Spacers.

Authors:  Sandrine Mariaux; Ulrika Furustrand Tafin; Olivier Borens
Journal:  J Bone Jt Infect       Date:  2018-03-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.