Literature DB >> 14563591

Cardiac resynchronization therapy for the treatment of heart failure in patients with intraventricular conduction delay and malignant ventricular tachyarrhythmias.

Steven L Higgins1, John D Hummel, Imran K Niazi, Michael C Giudici, Seth J Worley, Leslie A Saxon, John P Boehmer, Michael B Higginbotham, Teresa De Marco, Elyse Foster, Patrick G Yong.   

Abstract

OBJECTIVES: This study was conducted to assess the safety and effectiveness of cardiac resynchronization therapy (CRT) when combined with an implantable cardioverter defibrillator (ICD).
BACKGROUND: Long-term outcome of CRT was measured in patients with symptomatic heart failure (HF), intraventricular conduction delay, and malignant ventricular tachyarrhythmias (ventricular tachycardia/ventricular fibrillation [VT/VF]) requiring therapy from an ICD.
METHODS: Patients (n = 490) were implanted with a device capable of providing both CRT and ICD therapy and randomized to CRT (n = 245) or control (no CRT, n = 245) for up to six months. The primary end point was progression of HF, defined as all-cause mortality, hospitalization for HF, and VT/VF requiring device intervention. Secondary end points included peak oxygen consumption (VO(2)), 6-min walk (6 MW), New York Heart Association (NYHA) class, quality of life (QOL), and echocardiographic analysis.
RESULTS: A 15% reduction in HF progression was observed, but this was statistically insignificant (p = 0.35). The CRT, however, significantly improved peak VO(2) (0.8 ml/kg/min vs. 0.0 ml/kg/min, p = 0.030) and 6 MW (35 m vs. 15 m, p = 0.043). Changes in NYHA class (p = 0.10) and QOL (p = 0.40) were not statistically significant. The CRT demonstrated significant reductions in ventricular dimensions (left ventricular internal diameter in diastole = -3.4 mm vs. -0.3 mm, p < 0.001 and left ventricular internal diameter in systole = -4.0 mm vs. -0.7 mm, p < 0.001) and improvement in left ventricular ejection fraction (5.1% vs. 2.8%, p = 0.020). A subgroup of patients with advanced HF (NYHA class III/IV) consistently demonstrated improvement across all functional status end points.
CONCLUSIONS: The CRT improved functional status in patients indicated for an ICD who also have symptomatic HF and intraventricular conduction delay.

Entities:  

Mesh:

Year:  2003        PMID: 14563591     DOI: 10.1016/s0735-1097(03)01042-8

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  123 in total

Review 1.  Noninvasive assessment of the biventricular pacing system.

Authors:  Jonathan S Steinberg; Parimal B Maniar; Steven L Higgins; Sherie L Whiting; David B Meyer; Sergio Dubner; Abrar H Shah; David T Huang; Leslie A Saxon
Journal:  Ann Noninvasive Electrocardiol       Date:  2004-01       Impact factor: 1.468

Review 2.  The emerging role of cardiac resynchronization therapy in milder heart failure: are we implanting too late for response?

Authors:  Jason Bradfield; Noel G Boyle; Ravi Mandapati; Kalyanam Shivkumar
Journal:  Curr Heart Fail Rep       Date:  2012-03

3.  Increasing knowledge and changing views in cardiac resynchronization therapy.

Authors:  Laszlo Buga; John G F Cleland
Journal:  Heart Fail Rev       Date:  2012-11       Impact factor: 4.214

Review 4.  Cardiac resynchronization therapy in mild heart failure: a review of the REVERSE and MADIT-CRT trials.

Authors:  Carl R Reynolds; Michael R Gold
Journal:  Curr Cardiol Rep       Date:  2010-09       Impact factor: 2.931

5.  Impact of oxygen uptake efficiency slope as a marker of cardiorespiratory reserve on response to cardiac resynchronization therapy.

Authors:  Thomas Berger; Ralf Harun Zwick; Markus Stuehlinger; Wolfgang Dichtl; Gerhard Poelzl; Michael Edlinger; Otmar Pachinger; Florian Hintringer
Journal:  Clin Res Cardiol       Date:  2010-09-23       Impact factor: 5.460

Review 6.  [Cardiac contractility modulation. A new form of therapy for patients with heart failure and narrow QRS complex?].

Authors:  T Kleemann
Journal:  Herz       Date:  2015-11       Impact factor: 1.443

7.  Coronary sinus lead placement via the internal jugular vein in patients with advanced heart failure: a simplified percutaneous approach.

Authors:  Luis A Pires; Sohail A Hassan; Katrina M Johnson
Journal:  J Interv Card Electrophysiol       Date:  2005-03       Impact factor: 1.900

Review 8.  Cardiac resynchronization therapy.

Authors:  Brian T Schuler; Angel R León
Journal:  Curr Cardiol Rep       Date:  2005-09       Impact factor: 2.931

Review 9.  Standard and etiology-directed evidence-based therapies in myocarditis: state of the art and future perspectives.

Authors:  Bernhard Maisch; Sabine Pankuweit
Journal:  Heart Fail Rev       Date:  2013-11       Impact factor: 4.214

Review 10.  Devices in the management of advanced, chronic heart failure.

Authors:  William T Abraham; Sakima A Smith
Journal:  Nat Rev Cardiol       Date:  2012-12-11       Impact factor: 32.419

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.