Literature DB >> 14560208

Use of cine magnetic resonance angiography in quantifying aneurysm pulsatility associated with endoleak.

Peter L Faries1, Gautam Agarwal, Robert Lookstein, Joshua W Bernheim, Neal S Cayne, Hadley Cadot, Jeffery Goldman, K Craig Kent, Larry H Hollier, Michael L Marin.   

Abstract

OBJECTIVE: Persistent aneurysm perfusion or endoleak is associated with pulsatility of abdominal aortic aneurysm (AAA) after endovascular repair. However, the resultant pulsatile change in aneurysm diameter may be difficult to quantify, and therefore its significance is unknown. In this study cine magnetic resonance angiography (MRA) was used to quantify aneurysm wall motion during the cardiac cycle and to correlate it with the presence and type of endoleak.
METHODS: Cine MRA was performed in 16 patients undergoing endovascular repair of AAA. A 1.5 T magnet and post-processing with GEMS 4.0 Fiesta computerized video image analysis software were used to calculate maximum aortic diameter during systole and diastole. Changes in aortic diameter were determined from these measurements. Cine MRA was performed on aneurysms before treatment and in patients with and without endoleak after endovascular repair. Type of endoleak was confirmed at angiography in all cases. Four patients had antegrade (type I) endoleak, and eight patients had retrograde (type II) endoleak; no endoleak was present in four patients. Endovascular grafts with stent support throughout the entire length of the graft (Talent) were used in all cases (14 bifurcated grafts, 2 tube grafts).
RESULTS: Cine MRA demonstrated significantly greater wall motion and resultant change in aneurysm diameter in patients with type I endoleak compared with patients without endoleak (type I, 2.14 +/- 1.28 mm vs no endoleak, 0.12 +/- 0.09 mm, P =.001). Change in aneurysm diameter in patients with type II endoleak was not significantly greater than in patients with no endoleak (type II, 0.26 +/- 0.21 mm vs no endoleak, 0.12 +/- 0.09 mm, P = NS). Untreated aneurysms demonstrated the greatest change in diameter during the cardiac cycle (3.51 +/- 0.79 mm).
CONCLUSION: Cine MRA may be used to accurately quantify AAA wall motion before and after endovascular stent-graft treatment. The extent of change in diameter corresponds to the type of endoleak, with antegrade (type I) endoleak generating greater pulsatile change in diameter than retrograde-collateral (type II) endoleak or no endoleak. Cine MRA may provide a noninvasive means of assessing the success of endovascular treatment of AAA. Further studies will be necessary to confirm the utility and efficacy of cine MRA in postoperative assessment of endovascular aneurysm repair.

Entities:  

Mesh:

Year:  2003        PMID: 14560208     DOI: 10.1016/s0741-5214(03)00944-3

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  3 in total

1.  Endovascular therapy for thoracic aortic aneurysms: state of the art in 2012.

Authors:  Nicolas A Brozzi; Eric E Roselli
Journal:  Curr Treat Options Cardiovasc Med       Date:  2012-04

2.  Novel assessment of renal motion in children as measured via four-dimensional computed tomography.

Authors:  Atmaram S Pai Panandiker; Shelly Sharma; Mihir H Naik; Shengjie Wu; Chiaho Hua; Chris Beltran; Matthew J Krasin; Thomas E Merchant
Journal:  Int J Radiat Oncol Biol Phys       Date:  2011-05-27       Impact factor: 7.038

3.  Periostin links mechanical strain to inflammation in abdominal aortic aneurysm.

Authors:  Osamu Yamashita; Koichi Yoshimura; Ayako Nagasawa; Koshiro Ueda; Noriyasu Morikage; Yasuhiro Ikeda; Kimikazu Hamano
Journal:  PLoS One       Date:  2013-11-19       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.