Literature DB >> 14559339

Fast T2-weighted MR imaging: impact of variation in pulse sequence parameters on image quality and artifacts.

Tao Li1, Scott A Mirowitz.   

Abstract

The purpose of this study was to quantitatively evaluate in a phantom model the practical impact of alteration of key imaging parameters on image quality and artifacts for the most commonly used fast T(2)-weighted MR sequences. These include fast spin-echo (FSE), single shot fast spin-echo (SSFSE), and spin-echo echo-planar imaging (EPI) pulse sequences. We developed a composite phantom with different T1 and T2 values, which was evaluated while stationary as well as during periodic motion. Experiments involved controlled variations in key parameters including effective TE, TR, echo spacing (ESP), receive bandwidth (BW), echo train length (ETL), and shot number (SN). Quantitative analysis consisted of signal-to-noise ratio (SNR), image nonuniformity, full-width-at-half-maximum (i.e., blurring or geometric distortion) and ghosting ratio. Among the fast T(2)-weighted sequences, EPI was most sensitive to alterations in imaging parameters. Among imaging parameters that we tested, effective TE, ETL, and shot number most prominently affected image quality and artifacts. Short T(2) objects were more sensitive to alterations in imaging parameters in terms of image quality and artifacts. Optimal clinical application of these fast T(2)-weighted imaging pulse sequences requires careful attention to selection of imaging parameters.

Entities:  

Mesh:

Year:  2003        PMID: 14559339     DOI: 10.1016/s0730-725x(03)00173-5

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  13 in total

Review 1.  Fetal MRI: techniques and protocols.

Authors:  Daniela Prayer; Peter Christian Brugger; Lucas Prayer
Journal:  Pediatr Radiol       Date:  2004-07-28

2.  Magnetic resonance imaging: Review of imaging techniques and overview of liver imaging.

Authors:  Santhi Maniam; Janio Szklaruk
Journal:  World J Radiol       Date:  2010-08-28

3.  Interactive two-dimensional fresh blood imaging: a feasibility study.

Authors:  Pauline Wong; Martin J Graves; David J Lomas
Journal:  Eur Radiol       Date:  2008-11-04       Impact factor: 5.315

Review 4.  Motion-compensation techniques in neonatal and fetal MR imaging.

Authors:  C Malamateniou; S J Malik; S J Counsell; J M Allsop; A K McGuinness; T Hayat; K Broadhouse; R G Nunes; A M Ederies; J V Hajnal; M A Rutherford
Journal:  AJNR Am J Neuroradiol       Date:  2012-05-10       Impact factor: 3.825

5.  Some new angles on the magic angle: what MSK radiologists know and don't know about this phenomenon.

Authors:  Michael L Richardson; Behrang Amini; Todd L Richards
Journal:  Skeletal Radiol       Date:  2018-07-11       Impact factor: 2.199

6.  Transition into driven equilibrium of the balanced steady-state free precession as an ultrafast multisection T2-weighted imaging of the brain.

Authors:  Y-C K Huang; T-Y Huang; H-C Chiu; T-S Kuo; C-J Hsueh; H-W Kao; C-W Wang; H-H Hsu; C-J Juan
Journal:  AJNR Am J Neuroradiol       Date:  2014-04-10       Impact factor: 3.825

7.  Analysis of endoscopic third ventriculostomy patency by MRI: value of different pulse sequences, the sequence parameters, and the imaging planes for investigation of flow void.

Authors:  Alp Dinçer; Erdem Yildiz; Saeed Kohan; M Memet Özek
Journal:  Childs Nerv Syst       Date:  2010-07-15       Impact factor: 1.475

Review 8.  Functional magnetic resonance imaging for neurosurgical planning in neurooncology.

Authors:  Erik-Jan Vlieger; Charles B Majoie; Sieger Leenstra; Gerard J Den Heeten
Journal:  Eur Radiol       Date:  2004-05-18       Impact factor: 5.315

9.  Transvaginal ultrasound assessment of uterine scar after previous caesarean section: comparison with 3T-magnetic resonance diffusion tensor imaging.

Authors:  Federica Fiocchi; Elisabetta Petrella; Luca Nocetti; Serena Currà; Guido Ligabue; Tiziana Costi; Pietro Torricelli; Fabio Facchinetti
Journal:  Radiol Med       Date:  2014-08-07       Impact factor: 3.469

10.  Bias of cartilage T2 values related to method of calculation.

Authors:  Matthew F Koff; Kimberly K Amrami; Joel P Felmlee; Kenton R Kaufman
Journal:  Magn Reson Imaging       Date:  2008-05-07       Impact factor: 2.546